2015•Journal of Vacuum Science & Technology A Vacuum Surfaces and FilmsRequires access

Partial pressure measurement standard for characterizing partial pressure analyzers and measuring outgassing rates

Karl Jousten, Stephan Putzke, Joachim Buthig

Open publisher page 18 citations

Abstract

In this work, a measurement standard was established for partial pressures in high and ultrahigh vacuum conditions. Three (or more, with higher uncertainty) different gases with known partial pressures from 10−8 to 10−2 Pa can be generated in a calibration chamber of an ultrahigh vacuum system by a continuous expansion method. The ratio between two partial pressures can range from 10−6 to 1. The readings of partial pressure analyzers can be calibrated by comparing them to known partial pressures. The calibration chamber is connected to a sample chamber, where outgassing samples can be inserted via a load lock. With an in situ calibrated partial pressure analyzer, the outgassing rate from the samples can be measured in a traceable way to the international systems of units.

About this research paper

What this paper is about

In this work, a measurement standard was established for partial pressures in high and ultrahigh vacuum conditions. Three (or more, with higher uncertainty) different gases with known partial pressures from 10−8 to 10−2 Pa can be generated in a calibration chamber of an ultrahigh vacuum system by a continuous expansion method. The ratio between two partial pressures can range from 10−6 to 1. The readings of partial pressure analyzers can be calibrated by comparing them to known partial pressures. The calibration chamber is connected to a sample chamber, where outgassing samples can be inserted via a load lock. With an in situ calibrated partial pressure analyzer, the outgassing rate from the samples can be measured in a traceable way to the international systems of units.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this work, a measurement standard was established for partial pressures in high and ultrahigh vacuum conditions. Three (or more, with higher uncertainty) different gases with known partial pressures from 10−8 to 10−2 Pa can be generated in a calibration chamber of an ultrahigh vacuum system by a continuous expansion method. The ratio between two partial pressures can range from 10−6 to 1. The readings of partial pressure analyzers can be calibrated by comparing them to known partial pressures. The calibration chamber is connected to a sample chamber, where outgassing samples can be inserted via a load lock. With an in situ calibrated partial pressure analyzer, the outgassing rate from the samples can be measured in a traceable way to the international systems of units.

Key concepts: Outgassing, Partial pressure, Calibration, Analytical Chemistry (journal), Pressure measurement, Materials science, Vacuum chamber, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Partial pressure measurement standard for characterizing partial pressure analyzers and measuring outgassing rates — Research Paper | ScholarLens