2004PubMedRequires access

The optimal hepatocyte density for a hollow-fiber bioartificial liver.

Qingxiang Xu, Xitai Sun, Yudong Qiu, Heyuan Zhang, Yi‐Tao Ding

Open publisher page 8 citations

Abstract

A bioartificial liver (BAL) based on viable porcine hepatocytes can serve as a bridge to liver transplantation in patients with acute liver failure (ALF). To support liver functions, an adequate mass of hepatocytes is needed, which depends upon the cell density in the BAL device. This study evaluated the optimal density of hepatocytes within BAL devices that were constructed by perfusing porcine hepatocyte suspensions mixed with cytodex-3 into polysulfon hollow-fibers. The BAL devices were prepared with 6 different cell densities. The mass of hepatocytes in each device was evaluated for (a) cell viability, (b) ability to degrade diazepam, (c) ability to synthesize urea, (d) incorporation of [3H]-leucine into protein, (e) glucose-6-phosphatase activity, (f) total RNA content, and (g) p53 gene expression. Hepatocyte viability was about 90% in each device. With increasing hepatocyte density, the diazepam concentration in the medium decreased from 9.26 +/- 0.96 mg/L at 1 x 10(5) cells/ml to a minimum of 5.25 +/- 1.02 mg/L at 5 x 10(6) cells/ml and thereafter remained at low levels. Urea production and [3H]-leucine incorporation into protein increased progressively until the cell density reached 5 x 10(6)/ml and thereafter remained at high levels. Glucose-6-phosphatase activity and total RNA content stayed at high levels until the cell density reached 5 x 10(6)/ml and then progressively decreased. p53 gene expression differed from the other parameters, since it increased only when the cell density reached 5 x 10(7)/ml. In conclusion, the density of 5 x 10(6) cells/ml is a critical inflection point for most of the functional parameters, although p53 gene expression is not elevated at this cell density. These findings suggest that 5 x 10(6) cells/ml is the optimal hepatocyte density in the hollow-fiber BAL device.

About this research paper

What this paper is about

A bioartificial liver (BAL) based on viable porcine hepatocytes can serve as a bridge to liver transplantation in patients with acute liver failure (ALF). To support liver functions, an adequate mass of hepatocytes is needed, which depends upon the cell density in the BAL device. This study evaluated the optimal density of hepatocytes within BAL devices that were constructed by perfusing porcine hepatocyte suspensions mixed with cytodex-3 into polysulfon hollow-fibers. The BAL devices were prepared with 6 different cell densities. The mass of hepatocytes in each device was evaluated for (a) cell viability, (b) ability to degrade diazepam, (c) ability to synthesize urea, (d) incorporation of [3H]-leucine into protein, (e) glucose-6-phosphatase activity, (f) total RNA content, and (g) p53 gene expression. Hepatocyte viability was about 90% in each device. With increasing hepatocyte density, the diazepam concentration in the medium decreased from 9.26 +/- 0.96 mg/L at 1 x 10(5) cells/ml to a minimum of 5.25 +/- 1.02 mg/L at 5 x 10(6) cells/ml and thereafter remained at low levels. Urea production and [3H]-leucine incorporation into protein increased progressively until the cell density reached 5 x 10(6)/ml and thereafter remained at high levels. Glucose-6-phosphatase activity and total RNA content stayed at high levels until the cell density reached 5 x 10(6)/ml and then progressively decreased. p53 gene expression differed from the other parameters, since it increased only when the cell density reached 5 x 10(7)/ml. In conclusion, the density of 5 x 10(6) cells/ml is a critical inflection point for most of the functional parameters, although p53 gene expression is not elevated at this cell density. These findings suggest that 5 x 10(6) cells/ml is the optimal hepatocyte density in the hollow-fiber BAL device.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A bioartificial liver (BAL) based on viable porcine hepatocytes can serve as a bridge to liver transplantation in patients with acute liver failure (ALF). To support liver functions, an adequate mass of hepatocytes is needed, which depends upon the cell density in the BAL device. This study evaluated the optimal density of hepatocytes within BAL devices that were constructed by perfusing porcine hepatocyte suspensions mixed with cytodex-3 into polysulfon hollow-fibers. The BAL devices were prepared with 6 different cell densities. The mass of hepatocytes in each device was evaluated for (a) cell viability, (b) ability to degrade diazepam, (c) ability to synthesize urea, (d) incorporation of [3H]-leucine into protein, (e) glucose-6-phosphatase activity, (f) total RNA content, and (g) p53 gene expression. Hepatocyte viability was about 90% in each device. With increasing hepatocyte density, the diazepam concentration in the medium decreased from 9.26 +/- 0.96 mg/L at 1 x 10(5) cells/ml to a minimum of 5.25 +/- 1.02 mg/L at 5 x 10(6) cells/ml and thereafter remained at low levels. Urea production and [3H]-leucine incorporation into protein increased progressively until the cell density reached 5 x 10(6)/ml and thereafter remained at high levels. Glucose-6-phosphatase activity and total RNA content stayed at high levels until the cell density reached 5 x 10(6)/ml and then progressively decreased. p53 gene expression differed from the other parameters, since it increased only when the cell density reached 5 x 10(7)/ml. In conclusion, the density of 5 x 10(6) cells/ml is a critical inflection point for most of the functional parameters, although p53 gene expression is not elevated at this cell density. These findings suggest that 5 x 10(6) cells/ml is the optimal hepatocyte density in the hollow-fiber BAL device.

Key concepts: Bioartificial liver device, Hepatocyte, Urea, Chemistry, Viability assay, Cell, Alkaline phosphatase, Liver cell

Related papers

Back to paper searchBrowse research topicsOriginal source
The optimal hepatocyte density for a hollow-fiber bioartificial liver. — Research Paper | ScholarLens