2006Applied OpticsRequires access

Real-time differential refractometry without interferometry at a sensitivity level of 10^-6

Michael McClimans, Charles LaPlante, David Bonner, Samir Bali

Open publisher page 36 citations

Abstract

We present a refractometer based on the principle of total internal reflection that can sensitively record, in real time, the refractive index of fluids over a wide range of refractive indices. The device uses a divergent laser beam and a linear diode array, and has no mechanical or optical moving parts, enabling us to achieve the measurement of a refractive index at a sensitivity level of 10(-6). Our refractometer does not rely on interferometry, thus enabling the device to be compact, portable, and inexpensive. To the best of our knowledge, this is the first time a noninterferometric device that performs real-time differential refractometry with a sensitivity of better than 10(-5) has been demonstrated in the literature. We show that our experimental results agree very well with Fresnel theory. We establish a theoretical limit on the sensitivity of this class of refractometers.

About this research paper

What this paper is about

We present a refractometer based on the principle of total internal reflection that can sensitively record, in real time, the refractive index of fluids over a wide range of refractive indices. The device uses a divergent laser beam and a linear diode array, and has no mechanical or optical moving parts, enabling us to achieve the measurement of a refractive index at a sensitivity level of 10(-6). Our refractometer does not rely on interferometry, thus enabling the device to be compact, portable, and inexpensive. To the best of our knowledge, this is the first time a noninterferometric device that performs real-time differential refractometry with a sensitivity of better than 10(-5) has been demonstrated in the literature. We show that our experimental results agree very well with Fresnel theory. We establish a theoretical limit on the sensitivity of this class of refractometers.

Why it matters

OpenAlex reports 36 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We present a refractometer based on the principle of total internal reflection that can sensitively record, in real time, the refractive index of fluids over a wide range of refractive indices. The device uses a divergent laser beam and a linear diode array, and has no mechanical or optical moving parts, enabling us to achieve the measurement of a refractive index at a sensitivity level of 10(-6). Our refractometer does not rely on interferometry, thus enabling the device to be compact, portable, and inexpensive. To the best of our knowledge, this is the first time a noninterferometric device that performs real-time differential refractometry with a sensitivity of better than 10(-5) has been demonstrated in the literature. We show that our experimental results agree very well with Fresnel theory. We establish a theoretical limit on the sensitivity of this class of refractometers.

Key concepts: Refractometry, Refractometer, Optics, Refractive index, Sensitivity (control systems), Interferometry, Total internal reflection, Fresnel equations

Related papers

Back to paper searchBrowse research topicsOriginal source
Real-time differential refractometry without interferometry at a sensitivity level of 10^-6 — Research Paper | ScholarLens