1975Journal of Chromatographic ScienceRequires access

High-Speed Liquid Chromatographic Separation of Glycerides, Fatty Acids and Sterols

K. Kuichi, Teruo Ohta, Hideo Ebine

Open publisher page 21 citations

Abstract

The high-speed liquid chromatographic separation and detection of triglycerides, diglycerides, fatty acid and sterols was carried out to permit the analyses of total lipids from soybeans and soybean food. The study was conducted with a Varian Aerograph LC 1200 liquid chromatograph equipped with a hydrogen flame ionization detector. Linear-gradient, solvent-flow programming was used. Separation of the total lipids by the gradient was achieved in 30 minutes and the column prepared for the next analysis by washing with solvents. The detector response curves for authentic compounds were linear and equivalent to within 2.3% error, based on the response to 1-monopalmitin. The minimum detectable amounts of the authentic substances were between 0.1 and 1.4mug. When a three-stranded wire was used instead of single filament wire, the sensitivity was increased by 37%.

About this research paper

What this paper is about

The high-speed liquid chromatographic separation and detection of triglycerides, diglycerides, fatty acid and sterols was carried out to permit the analyses of total lipids from soybeans and soybean food. The study was conducted with a Varian Aerograph LC 1200 liquid chromatograph equipped with a hydrogen flame ionization detector. Linear-gradient, solvent-flow programming was used. Separation of the total lipids by the gradient was achieved in 30 minutes and the column prepared for the next analysis by washing with solvents. The detector response curves for authentic compounds were linear and equivalent to within 2.3% error, based on the response to 1-monopalmitin. The minimum detectable amounts of the authentic substances were between 0.1 and 1.4mug. When a three-stranded wire was used instead of single filament wire, the sensitivity was increased by 37%.

Why it matters

OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The high-speed liquid chromatographic separation and detection of triglycerides, diglycerides, fatty acid and sterols was carried out to permit the analyses of total lipids from soybeans and soybean food. The study was conducted with a Varian Aerograph LC 1200 liquid chromatograph equipped with a hydrogen flame ionization detector. Linear-gradient, solvent-flow programming was used. Separation of the total lipids by the gradient was achieved in 30 minutes and the column prepared for the next analysis by washing with solvents. The detector response curves for authentic compounds were linear and equivalent to within 2.3% error, based on the response to 1-monopalmitin. The minimum detectable amounts of the authentic substances were between 0.1 and 1.4mug. When a three-stranded wire was used instead of single filament wire, the sensitivity was increased by 37%.

Key concepts: Chemistry, Chromatography, Glyceride, Flame ionization detector, Chromatographic separation, Solvent, Fatty acid, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
High-Speed Liquid Chromatographic Separation of Glycerides, Fatty Acids and Sterols — Research Paper | ScholarLens