Abstract

Three assays were compared for the determination of total antioxidant capacity in human serum: the oxygen radical absorbance capacity (ORAC) assay, the Randox Trolox-equivalent antioxidant capacity (Randox-TEAC) assay, and the ferric reducing ability (FRAP) assay. There was a weak but significant linear correlation between serum ORAC and serum FRAP. There was no correlation either between serum ORAC and serum TEAC or between serum FRAP and serum TEAC. The effect of dilution on the serum TEAC value and the use of inhibition percentage at a fixed time, without considering the length of inhibition time in the quantitation of results, adversely affected the Randox-TEAC assay. The FRAP assay is simple and inexpensive but does not measure the SH-group-containing antioxidants. The ORAC assay has high specificity and responds to numerous antioxidants. By utilizing different extraction techniques in the ORAC assay, one can remove serum proteins and also make some gross differentiation between aqueous and lipid-soluble antioxidants. However, the ORAC assay requires approximately 60 min more than the FRAP or Randox-TEAC assay to quantitate results.

Open-access reader

About this research paper

What this paper is about

Three assays were compared for the determination of total antioxidant capacity in human serum: the oxygen radical absorbance capacity (ORAC) assay, the Randox Trolox-equivalent antioxidant capacity (Randox-TEAC) assay, and the ferric reducing ability (FRAP) assay. There was a weak but significant linear correlation between serum ORAC and serum FRAP. There was no correlation either between serum ORAC and serum TEAC or between serum FRAP and serum TEAC. The effect of dilution on the serum TEAC value and the use of inhibition percentage at a fixed time, without considering the length of inhibition time in the quantitation of results, adversely affected the Randox-TEAC assay. The FRAP assay is simple and inexpensive but does not measure the SH-group-containing antioxidants. The ORAC assay has high specificity and responds to numerous antioxidants. By utilizing different extraction techniques in the ORAC assay, one can remove serum proteins and also make some gross differentiation between aqueous and lipid-soluble antioxidants. However, the ORAC assay requires approximately 60 min more than the FRAP or Randox-TEAC assay to quantitate results.

Why it matters

OpenAlex reports 907 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Three assays were compared for the determination of total antioxidant capacity in human serum: the oxygen radical absorbance capacity (ORAC) assay, the Randox Trolox-equivalent antioxidant capacity (Randox-TEAC) assay, and the ferric reducing ability (FRAP) assay. There was a weak but significant linear correlation between serum ORAC and serum FRAP. There was no correlation either between serum ORAC and serum TEAC or between serum FRAP and serum TEAC. The effect of dilution on the serum TEAC value and the use of inhibition percentage at a fixed time, without considering the length of inhibition time in the quantitation of results, adversely affected the Randox-TEAC assay. The FRAP assay is simple and inexpensive but does not measure the SH-group-containing antioxidants. The ORAC assay has high specificity and responds to numerous antioxidants. By utilizing different extraction techniques in the ORAC assay, one can remove serum proteins and also make some gross differentiation between aqueous and lipid-soluble antioxidants. However, the ORAC assay requires approximately 60 min more than the FRAP or Randox-TEAC assay to quantitate results.