Sensitive Flow-Injection Chemiluminescence Determination of Metformin Based onN-Bromosuccinimide-fluorescein System
Zhouping Wang, Zhujun Zhang, Zhifeng Fu, Wanfen Luo, Xiao Zhang
Abstract
Zhouping Wang, Zhujun Zhang, Zhifeng Fu, Wanfen Luo, Xiao Zhang
Abstract
A novel and sensitive flow-injection chemiluminescence (CL) method for the determination of metformin in pharmaceutical formulations over the range of 7 × 10−9–3 × 10−5 g mL−1 is proposed in this article. The method is based on the CL produced during the oxidation of N-bromosuccinimide (NBS) in alkaline medium in the presence of fluorescein as an effective energy transfer agent. Use of cetyltrimethylammonium bromide (CTAB) as a sensitizer enhances the signal magnitude about 100 times. The detection limit is 2.3 × 10−9 g mL−1 (3σ) with a relative standard deviation of 2.7% (n = 11) at 1 × 10−7 g mL−1 metformin. Ninety samples can be determined per hour. The method was evaluated by carrying out a recovery study and by the analysis of commercial formulations. The results obtained compared well with those obtained by pharmacopoeia method and demonstrated good accuracy and precision. The possible reaction mechanism of the CL in the system is also discussed briefly.
OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A novel and sensitive flow-injection chemiluminescence (CL) method for the determination of metformin in pharmaceutical formulations over the range of 7 × 10−9–3 × 10−5 g mL−1 is proposed in this article. The method is based on the CL produced during the oxidation of N-bromosuccinimide (NBS) in alkaline medium in the presence of fluorescein as an effective energy transfer agent. Use of cetyltrimethylammonium bromide (CTAB) as a sensitizer enhances the signal magnitude about 100 times. The detection limit is 2.3 × 10−9 g mL−1 (3σ) with a relative standard deviation of 2.7% (n = 11) at 1 × 10−7 g mL−1 metformin. Ninety samples can be determined per hour. The method was evaluated by carrying out a recovery study and by the analysis of commercial formulations. The results obtained compared well with those obtained by pharmacopoeia method and demonstrated good accuracy and precision. The possible reaction mechanism of the CL in the system is also discussed briefly.
Key concepts: N-Bromosuccinimide, Chemistry, Chemiluminescence, Detection limit, Bromide, Relative standard deviation, Chromatography, Fluorescein