2006Journal of Endovascular TherapyRequires access

Arterial Puncture Site Management After Percutaneous Transluminal Procedures Using a Hemostatic Wound Dressing (Clo-Sur P.A.D.) Versus Conventional Manual Compression: A Randomized Controlled Trial

Wolfgang Mlekusch, Petra Dick, Markus Haumer, Schila Sabeti, Erich Minar, Martin Schillinger

Open publisher page 47 citations

Abstract

PURPOSE: To investigate the efficacy and safety of a novel hemostatic wound dressing designed for rapid hemostasis at arterial puncture sites. METHODS: Over a 15-month period, 209 consecutive patients were randomized to conventional manual compression (n=105) or the use of the Clo-Sur P.A.D. hemostatic device (n=104) after removal of the sheath. Puncture-related and device-related complications, time to hemostasis, time to ambulation, and patient and physician discomfort were recorded. RESULTS: In 209 patients, 21 (10.0%) puncture-related complications were observed, including 11 (5.3%) pseudoaneurysms, 9 (4.3%) hematomas, and 1 (0.5%) major bleeding complication. There was no significant difference (p=0.36) in complications between the hemostatic device (9/104, 8.7%) and the conventional group (12/105, 11.4%). In the hemostatic device group compared to the conventional group, respectively, the average time to hemostasis (13.6 versus 20.3 minutes; p<0.001), time to ambulation (6.5 versus 17.4 hours, p<0.001), patient discomfort (VAS 2.1 versus 4.7, p<0.001), and physician discomfort (VAS 3.8 versus 5.2, p<0.001) were significantly lower. Twenty (19%) sheath removals in the hemostatic device group were classified as a technical failure of the device. CONCLUSION: The use of this hemostatic wound dressing for arterial access site management after percutaneous vascular procedures significantly reduced the time to hemostasis, enabled early mobilization, and reduced patient discomfort without increasing the risk for complications compared to conventional manual compression. A high rate of technical failures, however, warrants further improvement before routine use can be recommended.

About this research paper

What this paper is about

PURPOSE: To investigate the efficacy and safety of a novel hemostatic wound dressing designed for rapid hemostasis at arterial puncture sites. METHODS: Over a 15-month period, 209 consecutive patients were randomized to conventional manual compression (n=105) or the use of the Clo-Sur P.A.D. hemostatic device (n=104) after removal of the sheath. Puncture-related and device-related complications, time to hemostasis, time to ambulation, and patient and physician discomfort were recorded. RESULTS: In 209 patients, 21 (10.0%) puncture-related complications were observed, including 11 (5.3%) pseudoaneurysms, 9 (4.3%) hematomas, and 1 (0.5%) major bleeding complication. There was no significant difference (p=0.36) in complications between the hemostatic device (9/104, 8.7%) and the conventional group (12/105, 11.4%). In the hemostatic device group compared to the conventional group, respectively, the average time to hemostasis (13.6 versus 20.3 minutes; p<0.001), time to ambulation (6.5 versus 17.4 hours, p<0.001), patient discomfort (VAS 2.1 versus 4.7, p<0.001), and physician discomfort (VAS 3.8 versus 5.2, p<0.001) were significantly lower. Twenty (19%) sheath removals in the hemostatic device group were classified as a technical failure of the device. CONCLUSION: The use of this hemostatic wound dressing for arterial access site management after percutaneous vascular procedures significantly reduced the time to hemostasis, enabled early mobilization, and reduced patient discomfort without increasing the risk for complications compared to conventional manual compression. A high rate of technical failures, however, warrants further improvement before routine use can be recommended.

Why it matters

OpenAlex reports 47 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To investigate the efficacy and safety of a novel hemostatic wound dressing designed for rapid hemostasis at arterial puncture sites. METHODS: Over a 15-month period, 209 consecutive patients were randomized to conventional manual compression (n=105) or the use of the Clo-Sur P.A.D. hemostatic device (n=104) after removal of the sheath. Puncture-related and device-related complications, time to hemostasis, time to ambulation, and patient and physician discomfort were recorded. RESULTS: In 209 patients, 21 (10.0%) puncture-related complications were observed, including 11 (5.3%) pseudoaneurysms, 9 (4.3%) hematomas, and 1 (0.5%) major bleeding complication. There was no significant difference (p=0.36) in complications between the hemostatic device (9/104, 8.7%) and the conventional group (12/105, 11.4%). In the hemostatic device group compared to the conventional group, respectively, the average time to hemostasis (13.6 versus 20.3 minutes; p<0.001), time to ambulation (6.5 versus 17.4 hours, p<0.001), patient discomfort (VAS 2.1 versus 4.7, p<0.001), and physician discomfort (VAS 3.8 versus 5.2, p<0.001) were significantly lower. Twenty (19%) sheath removals in the hemostatic device group were classified as a technical failure of the device. CONCLUSION: The use of this hemostatic wound dressing for arterial access site management after percutaneous vascular procedures significantly reduced the time to hemostasis, enabled early mobilization, and reduced patient discomfort without increasing the risk for complications compared to conventional manual compression. A high rate of technical failures, however, warrants further improvement before routine use can be recommended.

Key concepts: Medicine, Hemostasis, Surgery, Randomized controlled trial, Percutaneous, Complication, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
Arterial Puncture Site Management After Percutaneous Transluminal Procedures Using a Hemostatic Wound Dressing (Clo-Sur P.A.D.) Versus Conventional Manual Compression: A Randomized Controlled Trial — Research Paper | ScholarLens