2002IEEE Transactions on MagneticsRequires access

Improvement of the sensor system in magnetic flux leakage-type nondestructive testing (NDT)

Gwan Soo Park, Eun Sik Park

Open publisher page 91 citations

Abstract

In magnetic flux leakage (MFL)-type nondestructive testing (NDT) system, the sensitivity of MFL sensor depends on the change of the magnetic field, not just on the magnitude of the field. In this paper, the leakage parameter was defined to determine the operating point in saturation curves, and an optimum design method to determine the size of the magnet to maximize the MFL signals in NDT is described. For detecting the small depth defect, we also developed the back yoke sensor system. The sensitivity of the optimum sensor system is increased up to 200%. The computed MFL signals in the optimally designed system are verified by measurement using Hall sensors mounted on the six-legged PIG in an 8-in test pipe with defects. The rhombic defects could be successfully measured and identified from the weak defect signals.

About this research paper

What this paper is about

In magnetic flux leakage (MFL)-type nondestructive testing (NDT) system, the sensitivity of MFL sensor depends on the change of the magnetic field, not just on the magnitude of the field. In this paper, the leakage parameter was defined to determine the operating point in saturation curves, and an optimum design method to determine the size of the magnet to maximize the MFL signals in NDT is described. For detecting the small depth defect, we also developed the back yoke sensor system. The sensitivity of the optimum sensor system is increased up to 200%. The computed MFL signals in the optimally designed system are verified by measurement using Hall sensors mounted on the six-legged PIG in an 8-in test pipe with defects. The rhombic defects could be successfully measured and identified from the weak defect signals.

Why it matters

OpenAlex reports 91 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In magnetic flux leakage (MFL)-type nondestructive testing (NDT) system, the sensitivity of MFL sensor depends on the change of the magnetic field, not just on the magnitude of the field. In this paper, the leakage parameter was defined to determine the operating point in saturation curves, and an optimum design method to determine the size of the magnet to maximize the MFL signals in NDT is described. For detecting the small depth defect, we also developed the back yoke sensor system. The sensitivity of the optimum sensor system is increased up to 200%. The computed MFL signals in the optimally designed system are verified by measurement using Hall sensors mounted on the six-legged PIG in an 8-in test pipe with defects. The rhombic defects could be successfully measured and identified from the weak defect signals.

Key concepts: Magnetic flux leakage, Nondestructive testing, Hall effect sensor, Leakage (economics), Acoustics, Materials science, Magnetic field, Saturation (graph theory)

Related papers

Back to paper searchBrowse research topicsOriginal source
Improvement of the sensor system in magnetic flux leakage-type nondestructive testing (NDT) — Research Paper | ScholarLens