2011American Journal of Analytical ChemistryOpen access

Hydralazine Hydrochloride: An Alternative Complexometric Reagent for Total Iron Spotometric Determination

Arlan de Assis Gonsalves, Cleônia Roberta Melo Araújo, Cristiane Xavier Galhardo, Marília Oliveira Fonseca Goulart, Fabiane C. de Abreu

Open full text 6 citations

Abstract

An alternative spectrophotometric method has been developed for total iron determination using flow injection analysis (FIA). The procedure is based on the coordination reaction between hydralazine and Fe2+ ions, which results in the formation of a purple complex monitored at 538 nm. For determination of total iron, Fe3+ ions were reduced using ascorbic acid. Under optimized conditions, a linear calibration graph (0.1 - 6.0 ?g?ml–1; n = 6) was obtained. The method allows LOD (3? of blank/slope = 0.06 ?g?ml–1) and LOQ (10? of blank/slope = 0.22 ?g?ml–1). The RSD ((s/ ) × 100) for a mixed standard containing 0.60 ?g?ml–1 Fe2+ and Fe3+ was 0.10% (n = 10). Recoveries of spiked samples were 94.3% - 106.0%. The analytical frequency was 60 h–1. The effect of possible interferences has been studied. The procedure was successfully applied for analysis of environmental samples. The real samples results were comparable with those obtained by the official method considering a paired t-test and 95% of confidence level.

Open-access reader

About this research paper

What this paper is about

An alternative spectrophotometric method has been developed for total iron determination using flow injection analysis (FIA). The procedure is based on the coordination reaction between hydralazine and Fe2+ ions, which results in the formation of a purple complex monitored at 538 nm. For determination of total iron, Fe3+ ions were reduced using ascorbic acid. Under optimized conditions, a linear calibration graph (0.1 - 6.0 ?g?ml–1; n = 6) was obtained. The method allows LOD (3? of blank/slope = 0.06 ?g?ml–1) and LOQ (10? of blank/slope = 0.22 ?g?ml–1). The RSD ((s/ ) × 100) for a mixed standard containing 0.60 ?g?ml–1 Fe2+ and Fe3+ was 0.10% (n = 10). Recoveries of spiked samples were 94.3% - 106.0%. The analytical frequency was 60 h–1. The effect of possible interferences has been studied. The procedure was successfully applied for analysis of environmental samples. The real samples results were comparable with those obtained by the official method considering a paired t-test and 95% of confidence level.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An alternative spectrophotometric method has been developed for total iron determination using flow injection analysis (FIA). The procedure is based on the coordination reaction between hydralazine and Fe2+ ions, which results in the formation of a purple complex monitored at 538 nm. For determination of total iron, Fe3+ ions were reduced using ascorbic acid. Under optimized conditions, a linear calibration graph (0.1 - 6.0 ?g?ml–1; n = 6) was obtained. The method allows LOD (3? of blank/slope = 0.06 ?g?ml–1) and LOQ (10? of blank/slope = 0.22 ?g?ml–1). The RSD ((s/ ) × 100) for a mixed standard containing 0.60 ?g?ml–1 Fe2+ and Fe3+ was 0.10% (n = 10). Recoveries of spiked samples were 94.3% - 106.0%. The analytical frequency was 60 h–1. The effect of possible interferences has been studied. The procedure was successfully applied for analysis of environmental samples. The real samples results were comparable with those obtained by the official method considering a paired t-test and 95% of confidence level.

Key concepts: Chemistry, Reagent, Standard addition, Calibration curve, Ascorbic acid, Detection limit, Hydrochloride, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Hydralazine Hydrochloride: An Alternative Complexometric Reagent for Total Iron Spotometric Determination — Research Paper | ScholarLens