2009Biological and Pharmaceutical BulletinOpen access

A Simplified Method to Determine Five Cytochrome P450 Probe Drugs by HPLC in a Single Run

Ying Liu, Jianjie Jiao, Caili Zhang, Jianshi Lou

Open full text 28 citations

Abstract

A simplified, rapid, selective HPLC method for determining five cytochrome P450 (CYP) probe drugs in single run is described. The five specific probe substrates of caffeine, chlorzoxazone, tolbutamide, metoprolol and midazolam, together with the internal standard diazepam, were extracted using liquid-liquid extraction in rat plasma, followed by high-performance liquid chromatography (HPLC) using a C(18) column (5 microm particle size, 250x4.6 mm i.d.). The mobile phase consisted of a methanol and 50 mM phosphate buffer (pH 3.4, 65 : 35). All analytes were separated simultaneously in a single run that lasted less than 22 min. The detection limits range from 0.2-50 microg/ml for caffeine, 0.5-50 microg/ml for tolbutamide, metoprolol and midazolam, 0.2-100 microg/ml for chlorzoxazone, respectively. The intra- and inter-day precisions for five probe substrates were 1.38-11.10% and 3.39-11.33%, respectively, and the accuracy of five probe substrates ranged from 94.92-113.06% and 92.18-112.62%. The limit of quantification (LOQ) was 0.5 microg/ml for tolbutamide, midazolam and metoprolol, 0.2 microg/ml for caffeine and chlorzoxazone. The present method provides a robust, fast analytical tool for the five-probe drug cocktail. Finally, the method was suitable for determining the plasma concentration of these compounds and evaluating the CYP1A2, 2C9, 2D6, 2E1 and 3A4 activities in rats.

Open-access reader

About this research paper

What this paper is about

A simplified, rapid, selective HPLC method for determining five cytochrome P450 (CYP) probe drugs in single run is described. The five specific probe substrates of caffeine, chlorzoxazone, tolbutamide, metoprolol and midazolam, together with the internal standard diazepam, were extracted using liquid-liquid extraction in rat plasma, followed by high-performance liquid chromatography (HPLC) using a C(18) column (5 microm particle size, 250x4.6 mm i.d.). The mobile phase consisted of a methanol and 50 mM phosphate buffer (pH 3.4, 65 : 35). All analytes were separated simultaneously in a single run that lasted less than 22 min. The detection limits range from 0.2-50 microg/ml for caffeine, 0.5-50 microg/ml for tolbutamide, metoprolol and midazolam, 0.2-100 microg/ml for chlorzoxazone, respectively. The intra- and inter-day precisions for five probe substrates were 1.38-11.10% and 3.39-11.33%, respectively, and the accuracy of five probe substrates ranged from 94.92-113.06% and 92.18-112.62%. The limit of quantification (LOQ) was 0.5 microg/ml for tolbutamide, midazolam and metoprolol, 0.2 microg/ml for caffeine and chlorzoxazone. The present method provides a robust, fast analytical tool for the five-probe drug cocktail. Finally, the method was suitable for determining the plasma concentration of these compounds and evaluating the CYP1A2, 2C9, 2D6, 2E1 and 3A4 activities in rats.

Why it matters

OpenAlex reports 28 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simplified, rapid, selective HPLC method for determining five cytochrome P450 (CYP) probe drugs in single run is described. The five specific probe substrates of caffeine, chlorzoxazone, tolbutamide, metoprolol and midazolam, together with the internal standard diazepam, were extracted using liquid-liquid extraction in rat plasma, followed by high-performance liquid chromatography (HPLC) using a C(18) column (5 microm particle size, 250x4.6 mm i.d.). The mobile phase consisted of a methanol and 50 mM phosphate buffer (pH 3.4, 65 : 35). All analytes were separated simultaneously in a single run that lasted less than 22 min. The detection limits range from 0.2-50 microg/ml for caffeine, 0.5-50 microg/ml for tolbutamide, metoprolol and midazolam, 0.2-100 microg/ml for chlorzoxazone, respectively. The intra- and inter-day precisions for five probe substrates were 1.38-11.10% and 3.39-11.33%, respectively, and the accuracy of five probe substrates ranged from 94.92-113.06% and 92.18-112.62%. The limit of quantification (LOQ) was 0.5 microg/ml for tolbutamide, midazolam and metoprolol, 0.2 microg/ml for caffeine and chlorzoxazone. The present method provides a robust, fast analytical tool for the five-probe drug cocktail. Finally, the method was suitable for determining the plasma concentration of these compounds and evaluating the CYP1A2, 2C9, 2D6, 2E1 and 3A4 activities in rats.

Key concepts: Chlorzoxazone, Tolbutamide, Chromatography, Chemistry, High-performance liquid chromatography, Caffeine, Metoprolol, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
A Simplified Method to Determine Five Cytochrome P450 Probe Drugs by HPLC in a Single Run — Research Paper | ScholarLens