2006ElectroanalysisRequires access

Application of Elimination Voltammetry to the Resolution of Adenine and Cytosine Signals in Oligonucleotides II. Hetero‐Oligodeoxynucleotides with Different Sequences of Adenine and Cytosine Nucleotides

Libuše Trnková, František Jelen, Irena Postbieglová

Open publisher page 31 citations

Abstract

Abstract Elimination voltammetry with linear scan (EVLS) was applied to the resolution of reduction signals of adenine (A) and cytosine (C) residues in short synthetic hetero‐oligodeoxynucleotides (ODNs) with different sequences of A and C. The EVLS evaluation required linear sweep voltammograms measured on a hanging mercury drop electrode (HMDE) at different scan rates. Compared to linear sweep voltammetry (LSV) and usual voltammetric methods the EVLS is capable of resolving the overlapped A and C signals, specifically by using the elimination function which eliminates the charging and kinetic currents (Ic, Ik) and conserves the diffusion current (Id). Since for an adsorbed electroactive substance this elimination function yields a well readable peak–counterpeak signal, the adsorptive stripping (AdS) procedure was favorably used. The adsorption of ODNs was carried out at −0.1 V for accumulation time of 120 s under stirring. It was found that heights and potentials of LSV signals were affected by ODNs concentrations, pH, scan rates, time of accumulation, and stirring speed during the adsorption. While on LSV curves the only one reduction peak of A and C residues was observed in all ODNs, the EVLS yielded two separated peaks in dependence on A, C sequences and pH. Our results showed that the EVLS in connection with the AdS procedure is a useful tool for qualitative and quantitative studies of short ODNs and a promising sensitive method for the development of electrochemical sensor following the ODN sequences.

About this research paper

What this paper is about

Abstract Elimination voltammetry with linear scan (EVLS) was applied to the resolution of reduction signals of adenine (A) and cytosine (C) residues in short synthetic hetero‐oligodeoxynucleotides (ODNs) with different sequences of A and C. The EVLS evaluation required linear sweep voltammograms measured on a hanging mercury drop electrode (HMDE) at different scan rates. Compared to linear sweep voltammetry (LSV) and usual voltammetric methods the EVLS is capable of resolving the overlapped A and C signals, specifically by using the elimination function which eliminates the charging and kinetic currents (Ic, Ik) and conserves the diffusion current (Id). Since for an adsorbed electroactive substance this elimination function yields a well readable peak–counterpeak signal, the adsorptive stripping (AdS) procedure was favorably used. The adsorption of ODNs was carried out at −0.1 V for accumulation time of 120 s under stirring. It was found that heights and potentials of LSV signals were affected by ODNs concentrations, pH, scan rates, time of accumulation, and stirring speed during the adsorption. While on LSV curves the only one reduction peak of A and C residues was observed in all ODNs, the EVLS yielded two separated peaks in dependence on A, C sequences and pH. Our results showed that the EVLS in connection with the AdS procedure is a useful tool for qualitative and quantitative studies of short ODNs and a promising sensitive method for the development of electrochemical sensor following the ODN sequences.

Why it matters

OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Elimination voltammetry with linear scan (EVLS) was applied to the resolution of reduction signals of adenine (A) and cytosine (C) residues in short synthetic hetero‐oligodeoxynucleotides (ODNs) with different sequences of A and C. The EVLS evaluation required linear sweep voltammograms measured on a hanging mercury drop electrode (HMDE) at different scan rates. Compared to linear sweep voltammetry (LSV) and usual voltammetric methods the EVLS is capable of resolving the overlapped A and C signals, specifically by using the elimination function which eliminates the charging and kinetic currents (Ic, Ik) and conserves the diffusion current (Id). Since for an adsorbed electroactive substance this elimination function yields a well readable peak–counterpeak signal, the adsorptive stripping (AdS) procedure was favorably used. The adsorption of ODNs was carried out at −0.1 V for accumulation time of 120 s under stirring. It was found that heights and potentials of LSV signals were affected by ODNs concentrations, pH, scan rates, time of accumulation, and stirring speed during the adsorption. While on LSV curves the only one reduction peak of A and C residues was observed in all ODNs, the EVLS yielded two separated peaks in dependence on A, C sequences and pH. Our results showed that the EVLS in connection with the AdS procedure is a useful tool for qualitative and quantitative studies of short ODNs and a promising sensitive method for the development of electrochemical sensor following the ODN sequences.

Key concepts: Hanging mercury drop electrode, Chemistry, Linear sweep voltammetry, Voltammetry, Adsorption, Cytosine, Analytical Chemistry (journal), Electrochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of Elimination Voltammetry to the Resolution of Adenine and Cytosine Signals in Oligonucleotides II. Hetero‐Oligodeoxynucleotides with Different Sequences of Adenine and Cytosine Nucleotides — Research Paper | ScholarLens