1972IEEE Transactions on Power Apparatus and SystemsRequires access

A Half Cycle Air Blast Generator Breaker for High Power Testing Fields

Karl Kriechbaum

Open publisher page 1 citations

Abstract

Generator breakers in high-power testing fields, the back-up breakers, have the function of safety breakers: they have to protect both the generator and the test breaker from being overstressed by a short-circuit current of undesired duration. The heavy short-circuit currents of modern generators enforce the development of generator circuit-breakers of high breaking capacities. In this paper a generator c. b. is described having a rated breaking capacity of 160 kA at a service voltage of 15.4 kV. This circuit-breaker is a half-cycle breaker capable of interrupting a symmetrical current at the first current zero passage. Due to its short minimum arcing time this breaker is suitable for syn- chronized breaking operations and so permits an economical testing of circuit-breakers. This testing method is also described.

About this research paper

What this paper is about

Generator breakers in high-power testing fields, the back-up breakers, have the function of safety breakers: they have to protect both the generator and the test breaker from being overstressed by a short-circuit current of undesired duration. The heavy short-circuit currents of modern generators enforce the development of generator circuit-breakers of high breaking capacities. In this paper a generator c. b. is described having a rated breaking capacity of 160 kA at a service voltage of 15.4 kV. This circuit-breaker is a half-cycle breaker capable of interrupting a symmetrical current at the first current zero passage. Due to its short minimum arcing time this breaker is suitable for syn- chronized breaking operations and so permits an economical testing of circuit-breakers. This testing method is also described.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Generator breakers in high-power testing fields, the back-up breakers, have the function of safety breakers: they have to protect both the generator and the test breaker from being overstressed by a short-circuit current of undesired duration. The heavy short-circuit currents of modern generators enforce the development of generator circuit-breakers of high breaking capacities. In this paper a generator c. b. is described having a rated breaking capacity of 160 kA at a service voltage of 15.4 kV. This circuit-breaker is a half-cycle breaker capable of interrupting a symmetrical current at the first current zero passage. Due to its short minimum arcing time this breaker is suitable for syn- chronized breaking operations and so permits an economical testing of circuit-breakers. This testing method is also described.

Key concepts: Circuit breaker, Sulfur hexafluoride circuit breaker, Distribution board, Electrical engineering, Generator (circuit theory), Arc-fault circuit interrupter, Residual-current device, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
A Half Cycle Air Blast Generator Breaker for High Power Testing Fields — Research Paper | ScholarLens