Research on Breaker Breakdown and Protecting Measures of 500 kV Circuit Breakers
XU Dang-guo
Abstract
XU Dang-guo
Abstract
Four breaker breakdown are discribed in this paper.Either insulation defect or mechanical error may cause breaker breakdown of circuit breakers.And the faults cannot be cleared automatically when breakdown happened due to the system voltage.The fault current of breaker breakdown is quite small than the short circuit current as there is no phase to ground fault.None protection operates immediately when breaker breakdown happens and the electric-arc buries between breakers for few seconds.The circuit breaker and the SF6 gas may be damaged during the arc buries.The protecting devices do not operate until the breakdown between the contacts becomes a phase-to-ground and the fault current increases rapiddly.The circuit breakers of EHV transmission line with parralle reactor and breakers of generator-transformer unit have higher risk of breaker flashover than other circuit breakers.The reason of breaker flashover of circuit breakers are analyzed in this paper.Breaker flashover protection of circuit breaker are introduced to protect the circuit breakers from damagement during breaker breakdown faults.The protection setting and time delay of breaker flashover protection for circuit breaker of transmission lines and generator-transformers are discussed respectively.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Four breaker breakdown are discribed in this paper.Either insulation defect or mechanical error may cause breaker breakdown of circuit breakers.And the faults cannot be cleared automatically when breakdown happened due to the system voltage.The fault current of breaker breakdown is quite small than the short circuit current as there is no phase to ground fault.None protection operates immediately when breaker breakdown happens and the electric-arc buries between breakers for few seconds.The circuit breaker and the SF6 gas may be damaged during the arc buries.The protecting devices do not operate until the breakdown between the contacts becomes a phase-to-ground and the fault current increases rapiddly.The circuit breakers of EHV transmission line with parralle reactor and breakers of generator-transformer unit have higher risk of breaker flashover than other circuit breakers.The reason of breaker flashover of circuit breakers are analyzed in this paper.Breaker flashover protection of circuit breaker are introduced to protect the circuit breakers from damagement during breaker breakdown faults.The protection setting and time delay of breaker flashover protection for circuit breaker of transmission lines and generator-transformers are discussed respectively.
Key concepts: Circuit breaker, Sulfur hexafluoride circuit breaker, Residual-current device, Transient recovery voltage, Arc-fault circuit interrupter, Electrical engineering, Fuse (electrical), Engineering