1995•Archives of SurgeryRequires access

Increases in Intra-abdominal Pressure Affect Pulmonary Compliance

Farouck N. Obeid

Open publisher page 174 citations

Abstract

OBJECTIVES: To determine the effect of increased intra-abdominal pressure (IAP) on pulmonary compliance and to determine an effective means to measure IAP. DESIGN: A prospective study. SETTING: An urban tertiary care hospital. PATIENTS: Twenty-six adult patients undergoing laparoscopic cholecystectomy. INTERVENTIONS: Intra-operative management of laparoscopic cholecystectomy requiring endotracheal intubation with general anesthesia, nasogastric and urinary bladder catheters, and position changes. Additional interventions included use of a rectal manometer and a respiratory pressure module inserted within the ventilator circuit. MAIN OUTCOME MEASURES: Correlation of changes in IAP with changes in dynamic pulmonary compliance, measured as tidal volume/(end inspiratory pressure--end expiratory pressure) and comparison of three different measurement techniques (bladder, rectal, and gastric) with a standard technique (insufflation pressure) in three different positions (supine, Trendelenburg's, and reverse Trendelenburg's). RESULTS: Compliance was significantly related to insufflation pressure (P < .001) by analysis of variance. In the gas insufflation model, the mean increment in bladder pressure reflected most closely the IAP increment in the supine position (5.7 vs 6 mm Hg) but not in the Trendelenburg (2.1 vs 6 mm Hg) and reverse Trendelenburg positions (3.4 vs 6 mm Hg). Rectal and gastric pressures were also position dependent and technically less reliable. CONCLUSIONS: Increased IAP has a major influence on pulmonary compliance (50% decrease at 16 mm Hg). Measurements of IAP by intraorgan manometry are position dependent and may not accurately reflect the intraperitoneal pressure.

About this research paper

What this paper is about

OBJECTIVES: To determine the effect of increased intra-abdominal pressure (IAP) on pulmonary compliance and to determine an effective means to measure IAP. DESIGN: A prospective study. SETTING: An urban tertiary care hospital. PATIENTS: Twenty-six adult patients undergoing laparoscopic cholecystectomy. INTERVENTIONS: Intra-operative management of laparoscopic cholecystectomy requiring endotracheal intubation with general anesthesia, nasogastric and urinary bladder catheters, and position changes. Additional interventions included use of a rectal manometer and a respiratory pressure module inserted within the ventilator circuit. MAIN OUTCOME MEASURES: Correlation of changes in IAP with changes in dynamic pulmonary compliance, measured as tidal volume/(end inspiratory pressure--end expiratory pressure) and comparison of three different measurement techniques (bladder, rectal, and gastric) with a standard technique (insufflation pressure) in three different positions (supine, Trendelenburg's, and reverse Trendelenburg's). RESULTS: Compliance was significantly related to insufflation pressure (P < .001) by analysis of variance. In the gas insufflation model, the mean increment in bladder pressure reflected most closely the IAP increment in the supine position (5.7 vs 6 mm Hg) but not in the Trendelenburg (2.1 vs 6 mm Hg) and reverse Trendelenburg positions (3.4 vs 6 mm Hg). Rectal and gastric pressures were also position dependent and technically less reliable. CONCLUSIONS: Increased IAP has a major influence on pulmonary compliance (50% decrease at 16 mm Hg). Measurements of IAP by intraorgan manometry are position dependent and may not accurately reflect the intraperitoneal pressure.

Why it matters

OpenAlex reports 174 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: To determine the effect of increased intra-abdominal pressure (IAP) on pulmonary compliance and to determine an effective means to measure IAP. DESIGN: A prospective study. SETTING: An urban tertiary care hospital. PATIENTS: Twenty-six adult patients undergoing laparoscopic cholecystectomy. INTERVENTIONS: Intra-operative management of laparoscopic cholecystectomy requiring endotracheal intubation with general anesthesia, nasogastric and urinary bladder catheters, and position changes. Additional interventions included use of a rectal manometer and a respiratory pressure module inserted within the ventilator circuit. MAIN OUTCOME MEASURES: Correlation of changes in IAP with changes in dynamic pulmonary compliance, measured as tidal volume/(end inspiratory pressure--end expiratory pressure) and comparison of three different measurement techniques (bladder, rectal, and gastric) with a standard technique (insufflation pressure) in three different positions (supine, Trendelenburg's, and reverse Trendelenburg's). RESULTS: Compliance was significantly related to insufflation pressure (P < .001) by analysis of variance. In the gas insufflation model, the mean increment in bladder pressure reflected most closely the IAP increment in the supine position (5.7 vs 6 mm Hg) but not in the Trendelenburg (2.1 vs 6 mm Hg) and reverse Trendelenburg positions (3.4 vs 6 mm Hg). Rectal and gastric pressures were also position dependent and technically less reliable. CONCLUSIONS: Increased IAP has a major influence on pulmonary compliance (50% decrease at 16 mm Hg). Measurements of IAP by intraorgan manometry are position dependent and may not accurately reflect the intraperitoneal pressure.

Key concepts: Medicine, Trendelenburg, Supine position, Trendelenburg position, Anesthesia, Insufflation, Pulmonary compliance, Pneumoperitoneum

Related papers

Back to paper searchBrowse research topicsOriginal source
Increases in Intra-abdominal Pressure Affect Pulmonary Compliance — Research Paper | ScholarLens