Determination of Five Macrolide Antibiotic Residues in Eggs Using Liquid Chromatography/Electrospray Ionization Tandem Mass Spectrometry
Jian Wang, Daniel Leung, Fred Butterworth
Abstract
Jian Wang, Daniel Leung, Fred Butterworth
Abstract
A method using liquid chromatography electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) for the determination of trace levels of five macrolide antibiotics (spiramycin, tilmicosin, oleandomycin, erythromycin, and tylosin) in eggs is presented. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring (MRM) of two or three fragment ion transitions to provide a high degree of sensitivity and specificity for both quantification and confirmation. Matrix-matched standard calibration curves were used to achieve the best accuracy of the method. A fully nested experimental design was used to study the measurement uncertainty arising from intermediate precision and trueness or proportional bias. The overall recoveries, that is, those determined by the nested experiments, of spiramycin, tilmicosin, oleandomycin, erythromycin, and tylosin at fortified levels of 60, 100, 200, and 300 microg/kg were 96.8, 98.2, 98.3, 98.8, and 95.4%, respectively. The LC/ESI-MS/MS method detection limits (S/N > or = 3:1) of five macrolides were <1.0 microg/kg.
OpenAlex reports 90 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A method using liquid chromatography electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) for the determination of trace levels of five macrolide antibiotics (spiramycin, tilmicosin, oleandomycin, erythromycin, and tylosin) in eggs is presented. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring (MRM) of two or three fragment ion transitions to provide a high degree of sensitivity and specificity for both quantification and confirmation. Matrix-matched standard calibration curves were used to achieve the best accuracy of the method. A fully nested experimental design was used to study the measurement uncertainty arising from intermediate precision and trueness or proportional bias. The overall recoveries, that is, those determined by the nested experiments, of spiramycin, tilmicosin, oleandomycin, erythromycin, and tylosin at fortified levels of 60, 100, 200, and 300 microg/kg were 96.8, 98.2, 98.3, 98.8, and 95.4%, respectively. The LC/ESI-MS/MS method detection limits (S/N > or = 3:1) of five macrolides were <1.0 microg/kg.
Key concepts: Oleandomycin, Tylosin, Tilmicosin, Spiramycin, Chemistry, Chromatography, Electrospray ionization, Tandem mass spectrometry