Abnormal mammography and sonography associated with foreign-body giant-cell reaction after stereotactic vacuum-assisted breast biopsy with carbon marking
M. L. Ruiz-Delgado, José Antonio López-Ruiz, Alberto Saiz-López
Abstract
M. L. Ruiz-Delgado, José Antonio López-Ruiz, Alberto Saiz-López
Abstract
BACKGROUND: Carbon marking of the biopsy site and needle track following stereotactic breast biopsy in nonpalpable mammography-detected lesions provides for safe and accurate localization for subsequent surgical excision. No significant complications of carbon marking have been reported to date. PURPOSE: To report follow-up imaging findings and histological changes (foreign-body giant-cell reaction) attributable to the use of carbon marking after vacuum breast biopsies. MATERIAL AND METHODS: This was a retrospective study of 130 patients in a mammographic screening program with nonpalpable suspicious breast lesions that were referred for stereotactic directional vacuum-assisted breast biopsy with carbon marking. Histological diagnosis was benign in all cases, but 1-year follow-up mammograms demonstrated suspect findings in four of them. RESULTS: For all four patients, the results of the initial stereotactic vacuum-assisted biopsy were benign, but mammographic follow-up and ultrasound findings revealed suspicious changes that, in all cases, were histologically shown to be foreign-body giant-cell reactions attributable to the use of carbon. CONCLUSION: In four of 130 lesions (3%) that were carbon marked following stereotactic vacuum-assisted breast biopsy, and in which surgical excision was not required, the mammographic and ultrasound follow-up appearance of the breast simulated malignancy. The abnormality was attributable to the use of carbon, which represents a potential source of misdiagnosis.
OpenAlex reports 32 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND: Carbon marking of the biopsy site and needle track following stereotactic breast biopsy in nonpalpable mammography-detected lesions provides for safe and accurate localization for subsequent surgical excision. No significant complications of carbon marking have been reported to date. PURPOSE: To report follow-up imaging findings and histological changes (foreign-body giant-cell reaction) attributable to the use of carbon marking after vacuum breast biopsies. MATERIAL AND METHODS: This was a retrospective study of 130 patients in a mammographic screening program with nonpalpable suspicious breast lesions that were referred for stereotactic directional vacuum-assisted breast biopsy with carbon marking. Histological diagnosis was benign in all cases, but 1-year follow-up mammograms demonstrated suspect findings in four of them. RESULTS: For all four patients, the results of the initial stereotactic vacuum-assisted biopsy were benign, but mammographic follow-up and ultrasound findings revealed suspicious changes that, in all cases, were histologically shown to be foreign-body giant-cell reactions attributable to the use of carbon. CONCLUSION: In four of 130 lesions (3%) that were carbon marked following stereotactic vacuum-assisted breast biopsy, and in which surgical excision was not required, the mammographic and ultrasound follow-up appearance of the breast simulated malignancy. The abnormality was attributable to the use of carbon, which represents a potential source of misdiagnosis.
Key concepts: Medicine, Stereotactic biopsy, Biopsy, Breast biopsy, Radiology, Malignancy, Mammography, Breast imaging