Mammographic findings after 14-gauge automated needle and 14-gauge directional, vacuum-assisted stereotactic breast biopsies.
Fred Burbank
Abstract
Fred Burbank
Abstract
PURPOSE: To compare findings from first imaging follow-up mammography for breast lesions shown to be benign at stereotactic biopsy with 14-gauge automated needles or 14-gauge directional, vacuum-assisted probes. MATERIALS AND METHODS: In 495 stereotactic breast biopsies, the mammographic appearance of the biopsy site or target lesion was evaluated at first imaging follow-up with a four-point scale (1 = progression of lesion or suspicious interval change [repeat biopsy], 2 = no clinically relevant change, 3 = interval decrease in size of lesion or number of microcalcifications, and 4 = no residual mammographic lesion). An automated needle was used in 363 biopsies and a directional, vacuum-assisted probe was used in 132 biopsies. Patient and lesion variables and time to first imaging follow-up were compared for the two techniques. RESULTS: No biopsy site or target lesion was assigned a score of 1 at first imaging follow-up with either technique. No lesion was referred for repeat biopsy because of the mammographic appearance at first imaging follow-up. First imaging follow-up was performed an average of 6.6 months for the directional, vacuum-assisted biopsies and 8.6 months for the automated needle biopsies (P < .0001). This difference reflected a difference in scheduling methods. CONCLUSION: Directional, vacuum-assisted and automated needle breast biopsies produced no distortion or suspicious interval change at the biopsy site at the first follow-up mammographic examination.
OpenAlex reports 62 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: To compare findings from first imaging follow-up mammography for breast lesions shown to be benign at stereotactic biopsy with 14-gauge automated needles or 14-gauge directional, vacuum-assisted probes. MATERIALS AND METHODS: In 495 stereotactic breast biopsies, the mammographic appearance of the biopsy site or target lesion was evaluated at first imaging follow-up with a four-point scale (1 = progression of lesion or suspicious interval change [repeat biopsy], 2 = no clinically relevant change, 3 = interval decrease in size of lesion or number of microcalcifications, and 4 = no residual mammographic lesion). An automated needle was used in 363 biopsies and a directional, vacuum-assisted probe was used in 132 biopsies. Patient and lesion variables and time to first imaging follow-up were compared for the two techniques. RESULTS: No biopsy site or target lesion was assigned a score of 1 at first imaging follow-up with either technique. No lesion was referred for repeat biopsy because of the mammographic appearance at first imaging follow-up. First imaging follow-up was performed an average of 6.6 months for the directional, vacuum-assisted biopsies and 8.6 months for the automated needle biopsies (P < .0001). This difference reflected a difference in scheduling methods. CONCLUSION: Directional, vacuum-assisted and automated needle breast biopsies produced no distortion or suspicious interval change at the biopsy site at the first follow-up mammographic examination.
Key concepts: Medicine, Breast biopsy, Biopsy, Mammography, Stereotactic biopsy, Lesion, Radiology, Breast imaging