1993•AnaesthesiaRequires access

Fibreoptic intubation

H. E. JONES, A. C. PEARCE, Peter T Moore

Open publisher page 70 citations

Abstract

A randomised study was carried out in 60 patients to assess the influence of tracheal tube tip design on the ease of railroading a tracheal tube during fibreoptic intubation. A new design of tracheal tube with a tapered tip, without a bevel, was compared with a tracheal tube of standard design. The new design was found to be greatly superior in both oro- and nasotracheal fibreoptic intubation, when compared with the traditional tracheal tube (p < 0.001). The shape of the tip of a tracheal tube is an important determinant of the ease of railroading the tube over an inserted fibrescope.

About this research paper

What this paper is about

A randomised study was carried out in 60 patients to assess the influence of tracheal tube tip design on the ease of railroading a tracheal tube during fibreoptic intubation. A new design of tracheal tube with a tapered tip, without a bevel, was compared with a tracheal tube of standard design. The new design was found to be greatly superior in both oro- and nasotracheal fibreoptic intubation, when compared with the traditional tracheal tube (p < 0.001). The shape of the tip of a tracheal tube is an important determinant of the ease of railroading the tube over an inserted fibrescope.

Why it matters

OpenAlex reports 70 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A randomised study was carried out in 60 patients to assess the influence of tracheal tube tip design on the ease of railroading a tracheal tube during fibreoptic intubation. A new design of tracheal tube with a tapered tip, without a bevel, was compared with a tracheal tube of standard design. The new design was found to be greatly superior in both oro- and nasotracheal fibreoptic intubation, when compared with the traditional tracheal tube (p < 0.001). The shape of the tip of a tracheal tube is an important determinant of the ease of railroading the tube over an inserted fibrescope.

Key concepts: Tracheal tube, Medicine, Bevel, Tracheal intubation, Tube (container), Intubation, Nasotracheal intubation, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
Fibreoptic intubation — Research Paper | ScholarLens