1991Postgraduate Medical JournalOpen access

‘Tru-Cut’ needle biopsy of the liver: importance of the correct technique

Breminand Maharaj, S Pillay

Open full text 10 citations

Abstract

In order to determine which technique would provide adequate tissue for histological examination when the 'Tru-Cut' needle is used for liver biopsy, the livers of cadavers were biopsied by a single operator, under direct vision, using a 'Tru-Cut' needle. The modified breast biopsy technique either preceded or followed one of two alternative methods, one of which was recommended by the manufacturer, in a random manner. Thereafter, the biopsies were repeated using the alternative sequence. The mean length of the liver biopsy specimens that were obtained using the modified breast biopsy technique was 16.3 mm (range: 8-20 mm). The corresponding figures for the manufacturerer's method were 7.7 mm (range: 2-14 mm) and for the third technique were 2.7 mm (range: 0.5-8 mm). Three of the 40 specimens (7.5%) obtained using the latter technique fragmented when placed in formalin; this did not occur in any of the 40 specimens taken using the modified breast biopsy technique. This investigation indicates that the modified breast biopsy technique should be used when 'Tru-Cut' needle biopsy of the liver is performed. This provides specimens which are adequate for histological diagnosis. In addition, the safety of liver biopsy, which is compromised by poor technique, is improved. The alternative methods, including that recommended by the manufacturer, must be avoided.

Open-access reader

About this research paper

What this paper is about

In order to determine which technique would provide adequate tissue for histological examination when the 'Tru-Cut' needle is used for liver biopsy, the livers of cadavers were biopsied by a single operator, under direct vision, using a 'Tru-Cut' needle. The modified breast biopsy technique either preceded or followed one of two alternative methods, one of which was recommended by the manufacturer, in a random manner. Thereafter, the biopsies were repeated using the alternative sequence. The mean length of the liver biopsy specimens that were obtained using the modified breast biopsy technique was 16.3 mm (range: 8-20 mm). The corresponding figures for the manufacturerer's method were 7.7 mm (range: 2-14 mm) and for the third technique were 2.7 mm (range: 0.5-8 mm). Three of the 40 specimens (7.5%) obtained using the latter technique fragmented when placed in formalin; this did not occur in any of the 40 specimens taken using the modified breast biopsy technique. This investigation indicates that the modified breast biopsy technique should be used when 'Tru-Cut' needle biopsy of the liver is performed. This provides specimens which are adequate for histological diagnosis. In addition, the safety of liver biopsy, which is compromised by poor technique, is improved. The alternative methods, including that recommended by the manufacturer, must be avoided.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to determine which technique would provide adequate tissue for histological examination when the 'Tru-Cut' needle is used for liver biopsy, the livers of cadavers were biopsied by a single operator, under direct vision, using a 'Tru-Cut' needle. The modified breast biopsy technique either preceded or followed one of two alternative methods, one of which was recommended by the manufacturer, in a random manner. Thereafter, the biopsies were repeated using the alternative sequence. The mean length of the liver biopsy specimens that were obtained using the modified breast biopsy technique was 16.3 mm (range: 8-20 mm). The corresponding figures for the manufacturerer's method were 7.7 mm (range: 2-14 mm) and for the third technique were 2.7 mm (range: 0.5-8 mm). Three of the 40 specimens (7.5%) obtained using the latter technique fragmented when placed in formalin; this did not occur in any of the 40 specimens taken using the modified breast biopsy technique. This investigation indicates that the modified breast biopsy technique should be used when 'Tru-Cut' needle biopsy of the liver is performed. This provides specimens which are adequate for histological diagnosis. In addition, the safety of liver biopsy, which is compromised by poor technique, is improved. The alternative methods, including that recommended by the manufacturer, must be avoided.

Key concepts: Biopsy, Medicine, Liver biopsy, Needle biopsy, Radiology, Breast biopsy, Nuclear medicine, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
‘Tru-Cut’ needle biopsy of the liver: importance of the correct technique — Research Paper | ScholarLens