Po‐Thur Eve General‐33: Feasibility of a Multileaf Collimator and Method for Multi‐slice Tomotherapy

Patrick Cadman, Thomas Rock Mackie, Paul J. Reckwerdt

Open publisher page 0 citations

Abstract

Purpose: Current methods for delivery of serial or helical tomotherapy are based on a collimator design which can, at most, irradiate two slices simultaneously as the source rotates around the patient. We investigate the feasibility of a novel multileaf collimator design and method for multi‐slice tomotherapy. Method and Materials: The MLC incorporates a compact pivoting leaf design. Intensity modulation is achieved through binary actuation of adjacent leaves. Multiple leaf banks are employed for multi‐slice tomotherapy delivery. Each fan beam will have a different divergence in the axial direction. Two multi‐slice delivery methods are evaluated where (a) pitch is determined by a given collimated slice which does not irradiate beyond the adjacent slice (regular pitch) or (b) pitch is determined by different collimated slices irradiating the same region in the patient (multi‐slice pitch). Junctioning effects were studied for a cylindrical phantom irradiated with open (unmodulated) fan beams. Results: A prototype MLC leaf has been tested which can switch between open and closed positions in a few tens of milliseconds. Regular pitch delivery produced the greatest inhomogeneity between regions irradiated by different collimated slices. The proposed multi‐slice pitch delivery method avoids regular pitch junctioning effects by irradiating all areas with all collimated slices. Conclusions: These results indicate that multi‐slice tomotherapy is feasible with the benefits of shorter treatment times and it may allow for the use of Co‐60 as a tomotherapy radiation source. Conflict of Interest: Research was supported in part through a licensing agreement with TomoTherapy Inc.

About this research paper

What this paper is about

Purpose: Current methods for delivery of serial or helical tomotherapy are based on a collimator design which can, at most, irradiate two slices simultaneously as the source rotates around the patient. We investigate the feasibility of a novel multileaf collimator design and method for multi‐slice tomotherapy. Method and Materials: The MLC incorporates a compact pivoting leaf design. Intensity modulation is achieved through binary actuation of adjacent leaves. Multiple leaf banks are employed for multi‐slice tomotherapy delivery. Each fan beam will have a different divergence in the axial direction. Two multi‐slice delivery methods are evaluated where (a) pitch is determined by a given collimated slice which does not irradiate beyond the adjacent slice (regular pitch) or (b) pitch is determined by different collimated slices irradiating the same region in the patient (multi‐slice pitch). Junctioning effects were studied for a cylindrical phantom irradiated with open (unmodulated) fan beams. Results: A prototype MLC leaf has been tested which can switch between open and closed positions in a few tens of milliseconds. Regular pitch delivery produced the greatest inhomogeneity between regions irradiated by different collimated slices. The proposed multi‐slice pitch delivery method avoids regular pitch junctioning effects by irradiating all areas with all collimated slices. Conclusions: These results indicate that multi‐slice tomotherapy is feasible with the benefits of shorter treatment times and it may allow for the use of Co‐60 as a tomotherapy radiation source. Conflict of Interest: Research was supported in part through a licensing agreement with TomoTherapy Inc.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose: Current methods for delivery of serial or helical tomotherapy are based on a collimator design which can, at most, irradiate two slices simultaneously as the source rotates around the patient. We investigate the feasibility of a novel multileaf collimator design and method for multi‐slice tomotherapy. Method and Materials: The MLC incorporates a compact pivoting leaf design. Intensity modulation is achieved through binary actuation of adjacent leaves. Multiple leaf banks are employed for multi‐slice tomotherapy delivery. Each fan beam will have a different divergence in the axial direction. Two multi‐slice delivery methods are evaluated where (a) pitch is determined by a given collimated slice which does not irradiate beyond the adjacent slice (regular pitch) or (b) pitch is determined by different collimated slices irradiating the same region in the patient (multi‐slice pitch). Junctioning effects were studied for a cylindrical phantom irradiated with open (unmodulated) fan beams. Results: A prototype MLC leaf has been tested which can switch between open and closed positions in a few tens of milliseconds. Regular pitch delivery produced the greatest inhomogeneity between regions irradiated by different collimated slices. The proposed multi‐slice pitch delivery method avoids regular pitch junctioning effects by irradiating all areas with all collimated slices. Conclusions: These results indicate that multi‐slice tomotherapy is feasible with the benefits of shorter treatment times and it may allow for the use of Co‐60 as a tomotherapy radiation source. Conflict of Interest: Research was supported in part through a licensing agreement with TomoTherapy Inc.

Key concepts: Tomotherapy, Collimated light, Multileaf collimator, Collimator, Optics, Imaging phantom, Materials science, Beam (structure)

Related papers

Back to paper searchBrowse research topicsOriginal source
Po‐Thur Eve General‐33: Feasibility of a Multileaf Collimator and Method for Multi‐slice Tomotherapy — Research Paper | ScholarLens