2013Unpublished venueRequires access

Dual-core fluxgate gradiometer with gradient feedback

Michal Janošek, Antonı́n Platil, Jan Vyhnánek, Jan Brinek

Open publisher page 8 citations

Abstract

A fluxgate magnetic gradiometer with two fluxgate sensors and gradient feedback loop is presented. The two feedback coils, gradient and homogeneous, are common to both fluxgate sensors. The signal from the two sensors acts as regulating input in the two feedback loops, improving stability of the gradiometer. The presented gradiometer overcomes the problems of state-of-the art gradiometers which do not allow to decrease the sensor spacing. Because the information about homogeneous field is also available at the gradiometer output, it is possible to astatize the gradiometer. The presented gradiometer has a gradient base of 20-mm with overall sensor head size of 10-cm only and its noise is less than 1.1 nT/√Hz @ 1 Hz.

About this research paper

What this paper is about

A fluxgate magnetic gradiometer with two fluxgate sensors and gradient feedback loop is presented. The two feedback coils, gradient and homogeneous, are common to both fluxgate sensors. The signal from the two sensors acts as regulating input in the two feedback loops, improving stability of the gradiometer. The presented gradiometer overcomes the problems of state-of-the art gradiometers which do not allow to decrease the sensor spacing. Because the information about homogeneous field is also available at the gradiometer output, it is possible to astatize the gradiometer. The presented gradiometer has a gradient base of 20-mm with overall sensor head size of 10-cm only and its noise is less than 1.1 nT/√Hz @ 1 Hz.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A fluxgate magnetic gradiometer with two fluxgate sensors and gradient feedback loop is presented. The two feedback coils, gradient and homogeneous, are common to both fluxgate sensors. The signal from the two sensors acts as regulating input in the two feedback loops, improving stability of the gradiometer. The presented gradiometer overcomes the problems of state-of-the art gradiometers which do not allow to decrease the sensor spacing. Because the information about homogeneous field is also available at the gradiometer output, it is possible to astatize the gradiometer. The presented gradiometer has a gradient base of 20-mm with overall sensor head size of 10-cm only and its noise is less than 1.1 nT/√Hz @ 1 Hz.

Key concepts: Gradiometer, Fluxgate compass, Physics, Noise (video), Accelerometer, Acoustics, SIGNAL (programming language), Magnetic field