1990•Coronary Artery DiseaseRequires access

Paradoxical attenuation of fibrinolysis attributable to “plasminogen steal” and its implications for coronary thrombolysis

Burton E. Sobel, Denise A. Nachowiak, Edward T.A. Fry, Steven R. Bergmann, Sheryl R. Torr

Open publisher page 54 citations

Abstract

Clot-selective, relatively fibrin-specific plasminogen activators were initially developed because of the likelihood that they would preserve hemostatic integrity. Somewhat surprisingly, however, after intravenous administration they were found to induce coronary recanalization more rapidly and more frequently than first-generation agents. We hypothesized that their increased efficacy is related to sparing of free plasminogen and consequent preservation of the clot-associated plasminogen in equilibrium. To test this hypothesis, clots were formed from whole human blood in Chandler tubes and incubated with 100 to 8000 ng/mL of tissue-type plasminogen activator. At low concentrations, lysis was dose dependent. At concentrations exceeding 1500 ng/mL, paradoxical attenuation of lysis occurred by as much as 45%, associated with marked diminution of free plasminogen (greater than 80% depletion in 2 hours with 8000 ng/mL of tissue-type plasminogen activator). The decrease of free plasminogen was accompanied by depletion of clot-associated plasminogen measured in extracts. Prevention of both by repeated supplementation with plasminogen throughout incubations prevented attenuation of clot lysis, even with the highest concentrations of tissue-type plasminogen activator employed. The results indicate that depletion of free plasminogen, typical of that seen with all therapeutically effective doses of first-generation fibrinolytic agents in vivo, is likely to result in “plasminogen steal” and paradoxical attenuation of clot lysis

About this research paper

What this paper is about

Clot-selective, relatively fibrin-specific plasminogen activators were initially developed because of the likelihood that they would preserve hemostatic integrity. Somewhat surprisingly, however, after intravenous administration they were found to induce coronary recanalization more rapidly and more frequently than first-generation agents. We hypothesized that their increased efficacy is related to sparing of free plasminogen and consequent preservation of the clot-associated plasminogen in equilibrium. To test this hypothesis, clots were formed from whole human blood in Chandler tubes and incubated with 100 to 8000 ng/mL of tissue-type plasminogen activator. At low concentrations, lysis was dose dependent. At concentrations exceeding 1500 ng/mL, paradoxical attenuation of lysis occurred by as much as 45%, associated with marked diminution of free plasminogen (greater than 80% depletion in 2 hours with 8000 ng/mL of tissue-type plasminogen activator). The decrease of free plasminogen was accompanied by depletion of clot-associated plasminogen measured in extracts. Prevention of both by repeated supplementation with plasminogen throughout incubations prevented attenuation of clot lysis, even with the highest concentrations of tissue-type plasminogen activator employed. The results indicate that depletion of free plasminogen, typical of that seen with all therapeutically effective doses of first-generation fibrinolytic agents in vivo, is likely to result in “plasminogen steal” and paradoxical attenuation of clot lysis

Why it matters

OpenAlex reports 54 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Clot-selective, relatively fibrin-specific plasminogen activators were initially developed because of the likelihood that they would preserve hemostatic integrity. Somewhat surprisingly, however, after intravenous administration they were found to induce coronary recanalization more rapidly and more frequently than first-generation agents. We hypothesized that their increased efficacy is related to sparing of free plasminogen and consequent preservation of the clot-associated plasminogen in equilibrium. To test this hypothesis, clots were formed from whole human blood in Chandler tubes and incubated with 100 to 8000 ng/mL of tissue-type plasminogen activator. At low concentrations, lysis was dose dependent. At concentrations exceeding 1500 ng/mL, paradoxical attenuation of lysis occurred by as much as 45%, associated with marked diminution of free plasminogen (greater than 80% depletion in 2 hours with 8000 ng/mL of tissue-type plasminogen activator). The decrease of free plasminogen was accompanied by depletion of clot-associated plasminogen measured in extracts. Prevention of both by repeated supplementation with plasminogen throughout incubations prevented attenuation of clot lysis, even with the highest concentrations of tissue-type plasminogen activator employed. The results indicate that depletion of free plasminogen, typical of that seen with all therapeutically effective doses of first-generation fibrinolytic agents in vivo, is likely to result in “plasminogen steal” and paradoxical attenuation of clot lysis

Key concepts: Fibrinolysis, Thrombolysis, Fibrin, Plasminogen activator, Medicine, Lysis, Tissue plasminogen activator, T-plasminogen activator

Related papers

Back to paper searchBrowse research topicsOriginal source
Paradoxical attenuation of fibrinolysis attributable to “plasminogen steal” and its implications for coronary thrombolysis — Research Paper | ScholarLens