1996Journal of OpticsOpen access

Measurement of deviation of the microscope stage from squareness to the optical axis

Om Prakash, Rishi Ram

Open full text 0 citations

Abstract

The measurement of deviation of microscope stage from squareness to the optical axis is an important parameter in optical testing of microscopes. This test ensures that when the deviation is in the permitted limits, the optical axis of the microscope is normal to the stage and hence the movement of the microscope tube is in normal direction to the stage. In the present article a simple method to measure the deviation of the microscope stage from squareness to its optical axis has been described using a parallel plate and autocollimators. Test results on a few microscopes have been presented.

Open-access reader

About this research paper

What this paper is about

The measurement of deviation of microscope stage from squareness to the optical axis is an important parameter in optical testing of microscopes. This test ensures that when the deviation is in the permitted limits, the optical axis of the microscope is normal to the stage and hence the movement of the microscope tube is in normal direction to the stage. In the present article a simple method to measure the deviation of the microscope stage from squareness to its optical axis has been described using a parallel plate and autocollimators. Test results on a few microscopes have been presented.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The measurement of deviation of microscope stage from squareness to the optical axis is an important parameter in optical testing of microscopes. This test ensures that when the deviation is in the permitted limits, the optical axis of the microscope is normal to the stage and hence the movement of the microscope tube is in normal direction to the stage. In the present article a simple method to measure the deviation of the microscope stage from squareness to its optical axis has been described using a parallel plate and autocollimators. Test results on a few microscopes have been presented.

Key concepts: Microscope, Optical microscope, Optics, Optical axis, Materials science, Stage (stratigraphy), Microscopy, 4Pi microscope

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement of deviation of the microscope stage from squareness to the optical axis — Research Paper | ScholarLens