2014•Journal of the Chinese Chemical SocietyRequires access

Sensitive Voltammetric Determination of Cadmium(II) with 8‐Hydroxyquinoline and Ionic Liquid Modified Carbon Paste Electrode

Shaohui Jia, Shixing Gong, Yong Cheng, Huiyuhn Wang, Hejian Liu, Bo Zhang, Wei Sun

Open publisher page 2 citations

Abstract

Abstract In this paper 8‐hydroxyquinoline (HQ) and ionic liquid (IL) modified carbon paste electrode was fabricated and used for the sensitive determination of cadmium(II) with differential pulse anodic stripping voltammetry (DPASV). The modified electrode was prepared by the addition of HQ and IL 1‐ethyl‐3‐methylimidazoliam ethylsulphate as the modifiers into the traditional carbon paste mixture. Cd(II) was preconcentrated and reduced on the surface of the modified electrode at the potential of ‐1.0 V (vs. SCE) by the co‐contributions from the formation of HQ‐Cd(II) complex and the accumulation effect of IL. Then the reduced Cd on the electrode surface was reoxidized by DPASV with a sensitive oxidation peak appeared at ‐0.79 V (vs. SCE). Under the optimal conditions the oxidation peak current was proportional to the Cd(II) concentration in the range from 0.03 to 2.0 mol/L with the detection limit as 5.0 nmol/L (3σ). The proposed method was successfully applied to the water samples detection with the recovery in the range from 95.6% to 96.6%.

About this research paper

What this paper is about

Abstract In this paper 8‐hydroxyquinoline (HQ) and ionic liquid (IL) modified carbon paste electrode was fabricated and used for the sensitive determination of cadmium(II) with differential pulse anodic stripping voltammetry (DPASV). The modified electrode was prepared by the addition of HQ and IL 1‐ethyl‐3‐methylimidazoliam ethylsulphate as the modifiers into the traditional carbon paste mixture. Cd(II) was preconcentrated and reduced on the surface of the modified electrode at the potential of ‐1.0 V (vs. SCE) by the co‐contributions from the formation of HQ‐Cd(II) complex and the accumulation effect of IL. Then the reduced Cd on the electrode surface was reoxidized by DPASV with a sensitive oxidation peak appeared at ‐0.79 V (vs. SCE). Under the optimal conditions the oxidation peak current was proportional to the Cd(II) concentration in the range from 0.03 to 2.0 mol/L with the detection limit as 5.0 nmol/L (3σ). The proposed method was successfully applied to the water samples detection with the recovery in the range from 95.6% to 96.6%.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract In this paper 8‐hydroxyquinoline (HQ) and ionic liquid (IL) modified carbon paste electrode was fabricated and used for the sensitive determination of cadmium(II) with differential pulse anodic stripping voltammetry (DPASV). The modified electrode was prepared by the addition of HQ and IL 1‐ethyl‐3‐methylimidazoliam ethylsulphate as the modifiers into the traditional carbon paste mixture. Cd(II) was preconcentrated and reduced on the surface of the modified electrode at the potential of ‐1.0 V (vs. SCE) by the co‐contributions from the formation of HQ‐Cd(II) complex and the accumulation effect of IL. Then the reduced Cd on the electrode surface was reoxidized by DPASV with a sensitive oxidation peak appeared at ‐0.79 V (vs. SCE). Under the optimal conditions the oxidation peak current was proportional to the Cd(II) concentration in the range from 0.03 to 2.0 mol/L with the detection limit as 5.0 nmol/L (3σ). The proposed method was successfully applied to the water samples detection with the recovery in the range from 95.6% to 96.6%.

Key concepts: Chemistry, Anodic stripping voltammetry, 8-Hydroxyquinoline, Detection limit, Cadmium, Carbon paste electrode, Ionic liquid, Electrode

Related papers

Back to paper searchBrowse research topicsOriginal source
Sensitive Voltammetric Determination of Cadmium(II) with 8‐Hydroxyquinoline and Ionic Liquid Modified Carbon Paste Electrode — Research Paper | ScholarLens