2012Medical PhysicsRequires access

Calculation of strain images of a breast‐mimicking phantom from 3D CT image data

Jae G. Kim, A. B. M. Aowlad Hossain, Jong Hoon Shin, Soo Yong Lee

Open publisher page 12 citations

Abstract

PURPOSE: Elastography is a medical imaging modality to visualize the elasticity of soft tissues. Ultrasound and MRI have been exclusively used for elastography of soft tissues since they can sensitize the tissues' minute displacements of an order of μm. It is known that ultrasound and MRI elastography show cancerous tissues with much higher contrast than conventional ultrasound and MRI. To evaluate possibility of combining elastography with x-ray imaging, we have calculated strain images of a breast-mimicking phantom from its 3D CT image data. METHODS: We first simulated the x-ray elastography using a FEM model which incorporated both the elasticity and x-ray attenuation behaviors of breast tissues. After validating the x-ray elastography scheme by simulation, we made a breast-mimicking phantom that contained a hard inclusion against soft background. With a micro-CT, we took 3D images of the phantom twice, changing the compressing force to the phantom. From the two 3D phantom images taken with two different compression ratios, we calculated the displacement vector maps that represented the compression-induced pixel displacements. In calculating the displacement vectors, we tracked the movements of image feature patterns from the less-compressed-phantom images to the more-compressed-phantom images using the 3D image correlation technique. We obtained strain images of the phantom by differentiating the displacement vector maps. RESULTS: The FEM simulation has shown that x-ray strain imaging is possible by tracking image feature patterns in the 3D CT images of the breast-mimicking phantom. The experimental displacement and strain images of a breast-mimicking phantom, obtained from the 3D micro-CT images taken with 0%-3% compression ratios, show behaviors similar to the FEM simulation results. The contrast and noise performance of the strain images improves as the phantom compression ratio increases. CONCLUSIONS: We have experimentally shown that we can improve x-ray strain image quality by applying 3D image correlation to the two sets of 3D CT images taken with different compression ratios. But, we need further investigations to evaluate the strain imaging performance considering the noise and decorrelation effects as well as the extra dose caused by two scans.

About this research paper

What this paper is about

PURPOSE: Elastography is a medical imaging modality to visualize the elasticity of soft tissues. Ultrasound and MRI have been exclusively used for elastography of soft tissues since they can sensitize the tissues' minute displacements of an order of μm. It is known that ultrasound and MRI elastography show cancerous tissues with much higher contrast than conventional ultrasound and MRI. To evaluate possibility of combining elastography with x-ray imaging, we have calculated strain images of a breast-mimicking phantom from its 3D CT image data. METHODS: We first simulated the x-ray elastography using a FEM model which incorporated both the elasticity and x-ray attenuation behaviors of breast tissues. After validating the x-ray elastography scheme by simulation, we made a breast-mimicking phantom that contained a hard inclusion against soft background. With a micro-CT, we took 3D images of the phantom twice, changing the compressing force to the phantom. From the two 3D phantom images taken with two different compression ratios, we calculated the displacement vector maps that represented the compression-induced pixel displacements. In calculating the displacement vectors, we tracked the movements of image feature patterns from the less-compressed-phantom images to the more-compressed-phantom images using the 3D image correlation technique. We obtained strain images of the phantom by differentiating the displacement vector maps. RESULTS: The FEM simulation has shown that x-ray strain imaging is possible by tracking image feature patterns in the 3D CT images of the breast-mimicking phantom. The experimental displacement and strain images of a breast-mimicking phantom, obtained from the 3D micro-CT images taken with 0%-3% compression ratios, show behaviors similar to the FEM simulation results. The contrast and noise performance of the strain images improves as the phantom compression ratio increases. CONCLUSIONS: We have experimentally shown that we can improve x-ray strain image quality by applying 3D image correlation to the two sets of 3D CT images taken with different compression ratios. But, we need further investigations to evaluate the strain imaging performance considering the noise and decorrelation effects as well as the extra dose caused by two scans.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: Elastography is a medical imaging modality to visualize the elasticity of soft tissues. Ultrasound and MRI have been exclusively used for elastography of soft tissues since they can sensitize the tissues' minute displacements of an order of μm. It is known that ultrasound and MRI elastography show cancerous tissues with much higher contrast than conventional ultrasound and MRI. To evaluate possibility of combining elastography with x-ray imaging, we have calculated strain images of a breast-mimicking phantom from its 3D CT image data. METHODS: We first simulated the x-ray elastography using a FEM model which incorporated both the elasticity and x-ray attenuation behaviors of breast tissues. After validating the x-ray elastography scheme by simulation, we made a breast-mimicking phantom that contained a hard inclusion against soft background. With a micro-CT, we took 3D images of the phantom twice, changing the compressing force to the phantom. From the two 3D phantom images taken with two different compression ratios, we calculated the displacement vector maps that represented the compression-induced pixel displacements. In calculating the displacement vectors, we tracked the movements of image feature patterns from the less-compressed-phantom images to the more-compressed-phantom images using the 3D image correlation technique. We obtained strain images of the phantom by differentiating the displacement vector maps. RESULTS: The FEM simulation has shown that x-ray strain imaging is possible by tracking image feature patterns in the 3D CT images of the breast-mimicking phantom. The experimental displacement and strain images of a breast-mimicking phantom, obtained from the 3D micro-CT images taken with 0%-3% compression ratios, show behaviors similar to the FEM simulation results. The contrast and noise performance of the strain images improves as the phantom compression ratio increases. CONCLUSIONS: We have experimentally shown that we can improve x-ray strain image quality by applying 3D image correlation to the two sets of 3D CT images taken with different compression ratios. But, we need further investigations to evaluate the strain imaging performance considering the noise and decorrelation effects as well as the extra dose caused by two scans.

Key concepts: Imaging phantom, Elastography, Elasticity (physics), Displacement (psychology), Pixel, Medical imaging, 3D ultrasound, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Calculation of strain images of a breast‐mimicking phantom from 3D CT image data — Research Paper | ScholarLens