2005Obstetrical & Gynecological SurveyRequires access

Maternal Hemodynamics During Cesarean Delivery Assessed by Whole-Body Impedance Cardiography

Kati Maaria Hannele Tihtonen, Tirr K bi, Arvi Yu-Hankala, Jukka Tapio Uotila

Open publisher page 0 citations

Abstract

Whole-body impedance cardiography (ICGWB), a noninvasive procedure that provides continuous data on cardiac output, was used to assess hemodynamics and cardiovascular responses during elective cesarean section performed under spinal anesthesia in 10 healthy women with normal pregnancies. Five of these women were nulliparous. Two pregnant women with heart disease also were studied; one had aortic valve stenosis, and one had operated tetralogy of Fallot. Mean arterial pressure (MAP), heart rate (HR), stroke index (SI), cardiac index (CI), and systemic vascular resistance index (SVRI) were recorded during surgery, as anesthesia lightened, and 2 to 5 days postpartum. There were significant changes in all hemodynamic parameters over time (Fig. 3). Preloading increased both MAP and HR, but did not alter SI or CI. Spinal anesthesia led to lower SVRI, and MAP was significantly lower than after preloading. The CI and SI, however, remained unchanged. SVRI increased significantly in hypotonic patients given an infusion of ephedrine. Immediately after delivery, CI increased 47% over baseline and 34% from predelivery values. Both HR and SI increased significantly, but the MAP was stable—presumably because of a 39% decrease in SVRI. These changes lasted approximately 10 minutes on average but continued for 30 minutes in one instance. When ephedrine was not infused, hemodynamic responses to delivery resembled those in hypotonic patients. Baseline hemodynamic values returned after spinal blockade resolved. MAP was below baseline in the early postpartum period. CI was stable and SVRI tended to decline. The woman operated on for tetralogy of Fallot had normal baseline hemodynamic values. In the woman with aortic valve stenosis, the CI and the SI did not increase after delivery and pulmonary edema developed, from which she recovered completely. This experience indicates that ICGWB may provide a useful noninvasive means of monitoring hemodynamic changes during cesarean delivery.

About this research paper

What this paper is about

Whole-body impedance cardiography (ICGWB), a noninvasive procedure that provides continuous data on cardiac output, was used to assess hemodynamics and cardiovascular responses during elective cesarean section performed under spinal anesthesia in 10 healthy women with normal pregnancies. Five of these women were nulliparous. Two pregnant women with heart disease also were studied; one had aortic valve stenosis, and one had operated tetralogy of Fallot. Mean arterial pressure (MAP), heart rate (HR), stroke index (SI), cardiac index (CI), and systemic vascular resistance index (SVRI) were recorded during surgery, as anesthesia lightened, and 2 to 5 days postpartum. There were significant changes in all hemodynamic parameters over time (Fig. 3). Preloading increased both MAP and HR, but did not alter SI or CI. Spinal anesthesia led to lower SVRI, and MAP was significantly lower than after preloading. The CI and SI, however, remained unchanged. SVRI increased significantly in hypotonic patients given an infusion of ephedrine. Immediately after delivery, CI increased 47% over baseline and 34% from predelivery values. Both HR and SI increased significantly, but the MAP was stable—presumably because of a 39% decrease in SVRI. These changes lasted approximately 10 minutes on average but continued for 30 minutes in one instance. When ephedrine was not infused, hemodynamic responses to delivery resembled those in hypotonic patients. Baseline hemodynamic values returned after spinal blockade resolved. MAP was below baseline in the early postpartum period. CI was stable and SVRI tended to decline. The woman operated on for tetralogy of Fallot had normal baseline hemodynamic values. In the woman with aortic valve stenosis, the CI and the SI did not increase after delivery and pulmonary edema developed, from which she recovered completely. This experience indicates that ICGWB may provide a useful noninvasive means of monitoring hemodynamic changes during cesarean delivery.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Whole-body impedance cardiography (ICGWB), a noninvasive procedure that provides continuous data on cardiac output, was used to assess hemodynamics and cardiovascular responses during elective cesarean section performed under spinal anesthesia in 10 healthy women with normal pregnancies. Five of these women were nulliparous. Two pregnant women with heart disease also were studied; one had aortic valve stenosis, and one had operated tetralogy of Fallot. Mean arterial pressure (MAP), heart rate (HR), stroke index (SI), cardiac index (CI), and systemic vascular resistance index (SVRI) were recorded during surgery, as anesthesia lightened, and 2 to 5 days postpartum. There were significant changes in all hemodynamic parameters over time (Fig. 3). Preloading increased both MAP and HR, but did not alter SI or CI. Spinal anesthesia led to lower SVRI, and MAP was significantly lower than after preloading. The CI and SI, however, remained unchanged. SVRI increased significantly in hypotonic patients given an infusion of ephedrine. Immediately after delivery, CI increased 47% over baseline and 34% from predelivery values. Both HR and SI increased significantly, but the MAP was stable—presumably because of a 39% decrease in SVRI. These changes lasted approximately 10 minutes on average but continued for 30 minutes in one instance. When ephedrine was not infused, hemodynamic responses to delivery resembled those in hypotonic patients. Baseline hemodynamic values returned after spinal blockade resolved. MAP was below baseline in the early postpartum period. CI was stable and SVRI tended to decline. The woman operated on for tetralogy of Fallot had normal baseline hemodynamic values. In the woman with aortic valve stenosis, the CI and the SI did not increase after delivery and pulmonary edema developed, from which she recovered completely. This experience indicates that ICGWB may provide a useful noninvasive means of monitoring hemodynamic changes during cesarean delivery.

Key concepts: Medicine, Hemodynamics, Impedance cardiography, Vascular resistance, Anesthesia, Cardiac index, Heart rate, Cardiac output

Related papers

Back to paper searchBrowse research topicsOriginal source
Maternal Hemodynamics During Cesarean Delivery Assessed by Whole-Body Impedance Cardiography — Research Paper | ScholarLens