1986•Clinical PhysiologyRequires access

Clinical evaluation of impedance cardiography

David S. Goldstein, Richard O. Cannon, Reuven Zimlichman, H. R. Keiser

Open publisher page 78 citations

Abstract

We tested the validity of thoracic impedance cardiography for measuring cardiac output in man by comparing absolute values obtained using the non-invasive impedance method with values obtained using the invasive thermodilution method. We also compared per cent changes in cardiac output using impedance cardiography and thermodilution in response to environmental manipulations including cardiac pacing and intravenous administration of ergonovine, dipyridamole, or isoproterenol. Among 19 patients, absolute values for cardiac output, using the impedance and the thermodilution techniques, agreed well (r = 0.85, P less than 0.001). The per cent change in cardiac output by impedance cardiography was positively correlated with the per cent change by thermodilution for the several manipulations (overall r = 0.87, P less than 0.001). Impedance cardiography does appear, in general, to measure cardiac output and stroke volume validly in man, even in situations where heart rate and stroke volume change in opposite directions.

About this research paper

What this paper is about

We tested the validity of thoracic impedance cardiography for measuring cardiac output in man by comparing absolute values obtained using the non-invasive impedance method with values obtained using the invasive thermodilution method. We also compared per cent changes in cardiac output using impedance cardiography and thermodilution in response to environmental manipulations including cardiac pacing and intravenous administration of ergonovine, dipyridamole, or isoproterenol. Among 19 patients, absolute values for cardiac output, using the impedance and the thermodilution techniques, agreed well (r = 0.85, P less than 0.001). The per cent change in cardiac output by impedance cardiography was positively correlated with the per cent change by thermodilution for the several manipulations (overall r = 0.87, P less than 0.001). Impedance cardiography does appear, in general, to measure cardiac output and stroke volume validly in man, even in situations where heart rate and stroke volume change in opposite directions.

Why it matters

OpenAlex reports 78 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We tested the validity of thoracic impedance cardiography for measuring cardiac output in man by comparing absolute values obtained using the non-invasive impedance method with values obtained using the invasive thermodilution method. We also compared per cent changes in cardiac output using impedance cardiography and thermodilution in response to environmental manipulations including cardiac pacing and intravenous administration of ergonovine, dipyridamole, or isoproterenol. Among 19 patients, absolute values for cardiac output, using the impedance and the thermodilution techniques, agreed well (r = 0.85, P less than 0.001). The per cent change in cardiac output by impedance cardiography was positively correlated with the per cent change by thermodilution for the several manipulations (overall r = 0.87, P less than 0.001). Impedance cardiography does appear, in general, to measure cardiac output and stroke volume validly in man, even in situations where heart rate and stroke volume change in opposite directions.

Key concepts: Impedance cardiography, Medicine, Cardiology, Internal medicine, Stroke volume, Heart failure, Ejection fraction

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinical evaluation of impedance cardiography — Research Paper | ScholarLens