1967The Journal of the Acoustical Society of AmericaRequires access

Frequency Discrimination as Measured by AB and ABX Procedures

Michael G. Saslow

Open publisher page 2 citations

Abstract

It is often reported that difference thresholds for frequency when measured by an ABX procedure are at least twice as great as those measured by an AB procedure. The relationship has always been rationalized in terms of the greater phsyical and judgmental complexity of the ABX procedure. The present experiment was performed at 120 cps, 70 dB SPL, with two practiced subjects. For frequency differences of plus or minus 0.3 cps, or 0.25%, responses were 95% correct for ABX, and 82% correct for AB. This result contradicts the usual findings, and suggests a need for a new analysis of frequency-judgment mechanisms.

About this research paper

What this paper is about

It is often reported that difference thresholds for frequency when measured by an ABX procedure are at least twice as great as those measured by an AB procedure. The relationship has always been rationalized in terms of the greater phsyical and judgmental complexity of the ABX procedure. The present experiment was performed at 120 cps, 70 dB SPL, with two practiced subjects. For frequency differences of plus or minus 0.3 cps, or 0.25%, responses were 95% correct for ABX, and 82% correct for AB. This result contradicts the usual findings, and suggests a need for a new analysis of frequency-judgment mechanisms.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

It is often reported that difference thresholds for frequency when measured by an ABX procedure are at least twice as great as those measured by an AB procedure. The relationship has always been rationalized in terms of the greater phsyical and judgmental complexity of the ABX procedure. The present experiment was performed at 120 cps, 70 dB SPL, with two practiced subjects. For frequency differences of plus or minus 0.3 cps, or 0.25%, responses were 95% correct for ABX, and 82% correct for AB. This result contradicts the usual findings, and suggests a need for a new analysis of frequency-judgment mechanisms.

Key concepts: ABX test, Mathematics, Acoustics, Statistics, Audiology, Physics, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Frequency Discrimination as Measured by AB and ABX Procedures — Research Paper | ScholarLens