2005Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIERequires access

A comparison of doubly curved crystals and polycapillary optics for monochromatic beam production from a clinical source

Danhong Li, Noor Mail, Carolyn A. MacDonald

Open publisher page 1 citations

Abstract

Monochromatic beams produced with synchrotron sources are known to give higher contrast for mammography than clinical broadband sources. Monochromatic beams could also be achieved with clinical x-ray sources, by diffraction off of flat monochromator crystals, but monochromatic intensities are too low for imaging because only a small fraction of the incident beam is at the right energy and angle. With the use of polycapillary optics, monochromatic intensities could be increased. Two different x-ray optics schemes were tested to provide high monochromatic intensity from conventional divergent sources. A polycapillary collimating optic was employed to collect a large solid angle and redirect it into a parallel beam, which can be efficiently diffracted from a flat crystal. Measurements were performed for crystals of varying angular acceptance because there is a trade-off between intensity and resolution. Alternatively, doubly curved crystal (DCC) optics can be used to collect and focus monochromatic x rays from a divergence source. Higher monochromatic intensity can be obtained because the DCC optic diffracts and focuses the incident beam across the whole area of the crystal. For both methods, monochromatization occurs before the patient, resulting in a potential dose reduction as well as significant measured contrast enhancement. Measurements were made of contrast, resolution and intensity for the two techniques, and were compared to each other and to theoretical calculations.

About this research paper

What this paper is about

Monochromatic beams produced with synchrotron sources are known to give higher contrast for mammography than clinical broadband sources. Monochromatic beams could also be achieved with clinical x-ray sources, by diffraction off of flat monochromator crystals, but monochromatic intensities are too low for imaging because only a small fraction of the incident beam is at the right energy and angle. With the use of polycapillary optics, monochromatic intensities could be increased. Two different x-ray optics schemes were tested to provide high monochromatic intensity from conventional divergent sources. A polycapillary collimating optic was employed to collect a large solid angle and redirect it into a parallel beam, which can be efficiently diffracted from a flat crystal. Measurements were performed for crystals of varying angular acceptance because there is a trade-off between intensity and resolution. Alternatively, doubly curved crystal (DCC) optics can be used to collect and focus monochromatic x rays from a divergence source. Higher monochromatic intensity can be obtained because the DCC optic diffracts and focuses the incident beam across the whole area of the crystal. For both methods, monochromatization occurs before the patient, resulting in a potential dose reduction as well as significant measured contrast enhancement. Measurements were made of contrast, resolution and intensity for the two techniques, and were compared to each other and to theoretical calculations.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Monochromatic beams produced with synchrotron sources are known to give higher contrast for mammography than clinical broadband sources. Monochromatic beams could also be achieved with clinical x-ray sources, by diffraction off of flat monochromator crystals, but monochromatic intensities are too low for imaging because only a small fraction of the incident beam is at the right energy and angle. With the use of polycapillary optics, monochromatic intensities could be increased. Two different x-ray optics schemes were tested to provide high monochromatic intensity from conventional divergent sources. A polycapillary collimating optic was employed to collect a large solid angle and redirect it into a parallel beam, which can be efficiently diffracted from a flat crystal. Measurements were performed for crystals of varying angular acceptance because there is a trade-off between intensity and resolution. Alternatively, doubly curved crystal (DCC) optics can be used to collect and focus monochromatic x rays from a divergence source. Higher monochromatic intensity can be obtained because the DCC optic diffracts and focuses the incident beam across the whole area of the crystal. For both methods, monochromatization occurs before the patient, resulting in a potential dose reduction as well as significant measured contrast enhancement. Measurements were made of contrast, resolution and intensity for the two techniques, and were compared to each other and to theoretical calculations.

Key concepts: Monochromatic color, Optics, Collimated light, X-ray optics, Monochromator, Diffraction, Beam (structure), Synchrotron radiation

Related papers

Back to paper searchBrowse research topicsOriginal source
A comparison of doubly curved crystals and polycapillary optics for monochromatic beam production from a clinical source — Research Paper | ScholarLens