Monochromatic imaging with a conventional source using polycapillary x-ray optics

Francisca R. Sugiro, Carolyn A. MacDonald

Open publisher page 6 citations

Abstract

Monochromatic parallel beam imaging produces high subject contrast, high resolution, and low patient dose. Polycapillary collimating optics can be used to create a beam of sufficient intensity for monochromatization from a conventional source. Monochromatization is achieved by diffraction from a single crystal. Contrast, resolution, and intensity measurements were performed with both high and low angular acceptance crystals. Testing was first done at 8 keV with an intense copper rotating anode, then preliminary 17.5 keV measurements were made with a low power molybdenum source. At 8 keV, contrast enhancement was a factor of 5 relative to the polychromatic case, in good agreement with theoretical values. At 17.5 keV, monochromatic subject contrast is a factor of 2 times greater than the conventional polychromatic contrast. An additional factor of two increase in contrast is expected from the removal of scatter obtained from using the air gap which is allowable from the parallel beam. The measured angular resolution after the crystal was 0.6 mrad for a silicon crystal. The use of polycapillary collimating optics allowed monochromatic imaging measurements using a conventional rotating anode source and computed radiography plate in 300 mAs.

About this research paper

What this paper is about

Monochromatic parallel beam imaging produces high subject contrast, high resolution, and low patient dose. Polycapillary collimating optics can be used to create a beam of sufficient intensity for monochromatization from a conventional source. Monochromatization is achieved by diffraction from a single crystal. Contrast, resolution, and intensity measurements were performed with both high and low angular acceptance crystals. Testing was first done at 8 keV with an intense copper rotating anode, then preliminary 17.5 keV measurements were made with a low power molybdenum source. At 8 keV, contrast enhancement was a factor of 5 relative to the polychromatic case, in good agreement with theoretical values. At 17.5 keV, monochromatic subject contrast is a factor of 2 times greater than the conventional polychromatic contrast. An additional factor of two increase in contrast is expected from the removal of scatter obtained from using the air gap which is allowable from the parallel beam. The measured angular resolution after the crystal was 0.6 mrad for a silicon crystal. The use of polycapillary collimating optics allowed monochromatic imaging measurements using a conventional rotating anode source and computed radiography plate in 300 mAs.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Monochromatic parallel beam imaging produces high subject contrast, high resolution, and low patient dose. Polycapillary collimating optics can be used to create a beam of sufficient intensity for monochromatization from a conventional source. Monochromatization is achieved by diffraction from a single crystal. Contrast, resolution, and intensity measurements were performed with both high and low angular acceptance crystals. Testing was first done at 8 keV with an intense copper rotating anode, then preliminary 17.5 keV measurements were made with a low power molybdenum source. At 8 keV, contrast enhancement was a factor of 5 relative to the polychromatic case, in good agreement with theoretical values. At 17.5 keV, monochromatic subject contrast is a factor of 2 times greater than the conventional polychromatic contrast. An additional factor of two increase in contrast is expected from the removal of scatter obtained from using the air gap which is allowable from the parallel beam. The measured angular resolution after the crystal was 0.6 mrad for a silicon crystal. The use of polycapillary collimating optics allowed monochromatic imaging measurements using a conventional rotating anode source and computed radiography plate in 300 mAs.

Key concepts: Monochromatic color, Collimated light, Optics, Angular resolution (graph drawing), Resolution (logic), Beam (structure), Physics, Image resolution

Related papers

Back to paper searchBrowse research topicsOriginal source
Monochromatic imaging with a conventional source using polycapillary x-ray optics — Research Paper | ScholarLens