Dispersive Liquid-Liquid Microextraction Coupled with Gas Chromatography for the Determination of Orthochlorophenol in Environmental Water Samples
Ying Yang, Qian Sun, Chong Yi, Zhi Xiang Ye, Mo Li
Abstract
Ying Yang, Qian Sun, Chong Yi, Zhi Xiang Ye, Mo Li
Abstract
A rapid and effective method, the dispersive liquid-liquid microextraction(DLLME) with gas chromatography, has been developed for the extraction and determination of OCP in environmental water samples. The factors relevant to the efficiency of DLLME were investigated and optimized. Under the optimum conditions, such as 150μL of dichloromethane as extraction solvent, 1.2 mL acetone as dispersive agent, 8 minutes extraction time, and without salt addition, the linear response of this method was in the range of 0.5~5000μg L−1 (r = 0.9981), the relative standard deviation (RSD) for 500μg L−1 and 1000μg L−1 of OCP was 5.2% and 12.6% (n = 6), respectively. The detection limit (3σ) was 0.08 μg L−1. The developed method was successfully applied to the determination of trace amount of OCP in three kinds of real environmental water samples, the spiked recoveries were in the range of 87.4%~108.0%.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A rapid and effective method, the dispersive liquid-liquid microextraction(DLLME) with gas chromatography, has been developed for the extraction and determination of OCP in environmental water samples. The factors relevant to the efficiency of DLLME were investigated and optimized. Under the optimum conditions, such as 150μL of dichloromethane as extraction solvent, 1.2 mL acetone as dispersive agent, 8 minutes extraction time, and without salt addition, the linear response of this method was in the range of 0.5~5000μg L−1 (r = 0.9981), the relative standard deviation (RSD) for 500μg L−1 and 1000μg L−1 of OCP was 5.2% and 12.6% (n = 6), respectively. The detection limit (3σ) was 0.08 μg L−1. The developed method was successfully applied to the determination of trace amount of OCP in three kinds of real environmental water samples, the spiked recoveries were in the range of 87.4%~108.0%.
Key concepts: Chromatography, Dichloromethane, Detection limit, Extraction (chemistry), Acetone, Chemistry, Solvent, Linear range