Interaction between intrinsic positive end-expiratory pressure and externally applied positive end-expiratory pressure during controlled mechanical ventilation

Javier Muñoz, J.E. Guerrero, BRAULIO DE LA CALLE, José Luís Escalante

Open publisher page 13 citations

Abstract

OBJECTIVE: To assess the interaction between intrinsic and externally applied positive end-expiratory pressure (intrinsic PEEP and administered PEEP) in mechanically ventilated patients. DESIGN: Prospective study. SETTING: Intensive care unit of a university hospital. PATIENTS: Twelve consecutive critically ill patients. INTERVENTIONS: Application of an external PEEP of the same value as the intrinsic PEEP. MEASUREMENTS AND MAIN RESULTS: We found that when the administered PEEP was increased from 0 to the baseline value of intrinsic PEEP, mean intrinsic PEEP decreased from 6.5 +/- 4.2 (SD) to 1.3 +/- 0.7 cm H2O (p = .001). The mean end-inspiratory pressure was increased from 20.3 +/- 4.6 to 23.1 +/- 6.1 cm H2O (p < .05). The difference between the modification of intrinsic PEEP and the change in the end-inspiratory pressure was not significantly > 0 cm H2O. Thus, the increase in end-inspiratory pressure may be directly attributable to the increase in total PEEP (administered PEEP plus intrinsic PEEP). None of the other measurements of pulmonary mechanics changed (peak pressure, inspiratory resistance, compliance, and trapped-gas volume). CONCLUSIONS: The administration of positive end-expiratory pressure equal to the intrinsic positive end-expiratory pressure causes the almost total disappearance of the intrinsic positive end-expiratory pressure. When the administered positive end-expiratory pressure does not exceed the intrinsic positive end-expiratory pressure, the former is applied almost in its entirety to the patient's external circuit. The administration of positive end-expiratory pressure without prior quantification of the intrinsic positive end-expiratory pressure results in an overestimation of the beneficial effects of the administered positive end-expiratory pressure on the quasi-static compliance.

About this research paper

What this paper is about

OBJECTIVE: To assess the interaction between intrinsic and externally applied positive end-expiratory pressure (intrinsic PEEP and administered PEEP) in mechanically ventilated patients. DESIGN: Prospective study. SETTING: Intensive care unit of a university hospital. PATIENTS: Twelve consecutive critically ill patients. INTERVENTIONS: Application of an external PEEP of the same value as the intrinsic PEEP. MEASUREMENTS AND MAIN RESULTS: We found that when the administered PEEP was increased from 0 to the baseline value of intrinsic PEEP, mean intrinsic PEEP decreased from 6.5 +/- 4.2 (SD) to 1.3 +/- 0.7 cm H2O (p = .001). The mean end-inspiratory pressure was increased from 20.3 +/- 4.6 to 23.1 +/- 6.1 cm H2O (p < .05). The difference between the modification of intrinsic PEEP and the change in the end-inspiratory pressure was not significantly > 0 cm H2O. Thus, the increase in end-inspiratory pressure may be directly attributable to the increase in total PEEP (administered PEEP plus intrinsic PEEP). None of the other measurements of pulmonary mechanics changed (peak pressure, inspiratory resistance, compliance, and trapped-gas volume). CONCLUSIONS: The administration of positive end-expiratory pressure equal to the intrinsic positive end-expiratory pressure causes the almost total disappearance of the intrinsic positive end-expiratory pressure. When the administered positive end-expiratory pressure does not exceed the intrinsic positive end-expiratory pressure, the former is applied almost in its entirety to the patient's external circuit. The administration of positive end-expiratory pressure without prior quantification of the intrinsic positive end-expiratory pressure results in an overestimation of the beneficial effects of the administered positive end-expiratory pressure on the quasi-static compliance.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To assess the interaction between intrinsic and externally applied positive end-expiratory pressure (intrinsic PEEP and administered PEEP) in mechanically ventilated patients. DESIGN: Prospective study. SETTING: Intensive care unit of a university hospital. PATIENTS: Twelve consecutive critically ill patients. INTERVENTIONS: Application of an external PEEP of the same value as the intrinsic PEEP. MEASUREMENTS AND MAIN RESULTS: We found that when the administered PEEP was increased from 0 to the baseline value of intrinsic PEEP, mean intrinsic PEEP decreased from 6.5 +/- 4.2 (SD) to 1.3 +/- 0.7 cm H2O (p = .001). The mean end-inspiratory pressure was increased from 20.3 +/- 4.6 to 23.1 +/- 6.1 cm H2O (p < .05). The difference between the modification of intrinsic PEEP and the change in the end-inspiratory pressure was not significantly > 0 cm H2O. Thus, the increase in end-inspiratory pressure may be directly attributable to the increase in total PEEP (administered PEEP plus intrinsic PEEP). None of the other measurements of pulmonary mechanics changed (peak pressure, inspiratory resistance, compliance, and trapped-gas volume). CONCLUSIONS: The administration of positive end-expiratory pressure equal to the intrinsic positive end-expiratory pressure causes the almost total disappearance of the intrinsic positive end-expiratory pressure. When the administered positive end-expiratory pressure does not exceed the intrinsic positive end-expiratory pressure, the former is applied almost in its entirety to the patient's external circuit. The administration of positive end-expiratory pressure without prior quantification of the intrinsic positive end-expiratory pressure results in an overestimation of the beneficial effects of the administered positive end-expiratory pressure on the quasi-static compliance.

Key concepts: Positive end-expiratory pressure, Medicine, Mechanical ventilation, Anesthesia, Positive pressure, Artificial ventilation, Cardiology, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Interaction between intrinsic positive end-expiratory pressure and externally applied positive end-expiratory pressure during controlled mechanical ventilation — Research Paper | ScholarLens