2011Unpublished venueRequires access

Partial discharge measurement and pattern recognition in gas insulated switchgear

Hong‐Chan Chang, Feng‐Chang Gu, Hung‐Cheng Chen, Cheng‐Chien Kuo

Open publisher page 8 citations

Abstract

Gas insulated switchgear (GIS) has been widely used as main switching equipment in the power substation, because it has good insulation and high reliability. However, if the switchgear is with defect or beyond the server life, the ability of the insulation may be degradation. Therefore, the detecting technology and fault diagnostic method on GIS has become more and more importance. In this paper, four common defect types of 15 kV switchgears are established, and a commercial inductive sensor measures the current signal caused by the partial discharge (PD) phenomenon. Next transfer this current signal into 3D PD patterns, through these PD patterns we can find the differences characteristic among these testing models. Finally features extract and pattern recognition based on neural network (NN). This detection could determine types of failure and so assist in utility maintenance.

About this research paper

What this paper is about

Gas insulated switchgear (GIS) has been widely used as main switching equipment in the power substation, because it has good insulation and high reliability. However, if the switchgear is with defect or beyond the server life, the ability of the insulation may be degradation. Therefore, the detecting technology and fault diagnostic method on GIS has become more and more importance. In this paper, four common defect types of 15 kV switchgears are established, and a commercial inductive sensor measures the current signal caused by the partial discharge (PD) phenomenon. Next transfer this current signal into 3D PD patterns, through these PD patterns we can find the differences characteristic among these testing models. Finally features extract and pattern recognition based on neural network (NN). This detection could determine types of failure and so assist in utility maintenance.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Gas insulated switchgear (GIS) has been widely used as main switching equipment in the power substation, because it has good insulation and high reliability. However, if the switchgear is with defect or beyond the server life, the ability of the insulation may be degradation. Therefore, the detecting technology and fault diagnostic method on GIS has become more and more importance. In this paper, four common defect types of 15 kV switchgears are established, and a commercial inductive sensor measures the current signal caused by the partial discharge (PD) phenomenon. Next transfer this current signal into 3D PD patterns, through these PD patterns we can find the differences characteristic among these testing models. Finally features extract and pattern recognition based on neural network (NN). This detection could determine types of failure and so assist in utility maintenance.

Key concepts: Switchgear, Partial discharge, Reliability (semiconductor), Fault (geology), SIGNAL (programming language), Reliability engineering, Current (fluid), Electrical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Partial discharge measurement and pattern recognition in gas insulated switchgear — Research Paper | ScholarLens