1980The Journal of Toxicological SciencesOpen access

RAPID DETERMINATION OF CARBOXYHEMOGLOBIN BY ABSORBANCE DIFFERENCE BETWEEN DOUBLE WAVE LENGTH

Masakatsu Sakata, Masanobu Haga

Open full text 3 citations

Abstract

A spectrophotometric determination of CO-Hb content was investigated on the basis of double wavelength spectrophotometry. Absorbance differences at the two wavelengths at which O2-Hb has the same absorbance reflect only the CO-Hb component because the O2-Hb component is nulled out from the mixture of O2-Hb and CO-Hb. After measurement of absorbance difference, the measuring solution was saturated with pure CO and remeasured. CO-Hb % was calculated from the ratio of the absorbance differences. Since temperature significantly influences the spectrum of hemoglobin pigment, the wavelength pair changed with temperature. For accurate measurement, it was necessary to control temperature of diluting solution before dilution. Liberation of CO fro CO-Hb was observed at more than 80% CO-Hb, and 5% and 2% liberation from 100% CO-Hb occured at 100-fold dilution with 10 mm cuvette and 20-fold dilution with 2 mm cuvette respectively. Advantages of this method are that the standard curve or equation for calculation and accurate dilution are not necessary because the interfering component is nulled out and 100% CO-Hb of the standard sample is made with the same sample; and measurement is very rapid, taking less than 2 min.

Open-access reader

About this research paper

What this paper is about

A spectrophotometric determination of CO-Hb content was investigated on the basis of double wavelength spectrophotometry. Absorbance differences at the two wavelengths at which O2-Hb has the same absorbance reflect only the CO-Hb component because the O2-Hb component is nulled out from the mixture of O2-Hb and CO-Hb. After measurement of absorbance difference, the measuring solution was saturated with pure CO and remeasured. CO-Hb % was calculated from the ratio of the absorbance differences. Since temperature significantly influences the spectrum of hemoglobin pigment, the wavelength pair changed with temperature. For accurate measurement, it was necessary to control temperature of diluting solution before dilution. Liberation of CO fro CO-Hb was observed at more than 80% CO-Hb, and 5% and 2% liberation from 100% CO-Hb occured at 100-fold dilution with 10 mm cuvette and 20-fold dilution with 2 mm cuvette respectively. Advantages of this method are that the standard curve or equation for calculation and accurate dilution are not necessary because the interfering component is nulled out and 100% CO-Hb of the standard sample is made with the same sample; and measurement is very rapid, taking less than 2 min.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A spectrophotometric determination of CO-Hb content was investigated on the basis of double wavelength spectrophotometry. Absorbance differences at the two wavelengths at which O2-Hb has the same absorbance reflect only the CO-Hb component because the O2-Hb component is nulled out from the mixture of O2-Hb and CO-Hb. After measurement of absorbance difference, the measuring solution was saturated with pure CO and remeasured. CO-Hb % was calculated from the ratio of the absorbance differences. Since temperature significantly influences the spectrum of hemoglobin pigment, the wavelength pair changed with temperature. For accurate measurement, it was necessary to control temperature of diluting solution before dilution. Liberation of CO fro CO-Hb was observed at more than 80% CO-Hb, and 5% and 2% liberation from 100% CO-Hb occured at 100-fold dilution with 10 mm cuvette and 20-fold dilution with 2 mm cuvette respectively. Advantages of this method are that the standard curve or equation for calculation and accurate dilution are not necessary because the interfering component is nulled out and 100% CO-Hb of the standard sample is made with the same sample; and measurement is very rapid, taking less than 2 min.

Key concepts: Absorbance, Cuvette, Dilution, Chemistry, Analytical Chemistry (journal), Spectrophotometry, Wavelength, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
RAPID DETERMINATION OF CARBOXYHEMOGLOBIN BY ABSORBANCE DIFFERENCE BETWEEN DOUBLE WAVE LENGTH — Research Paper | ScholarLens