1997Journal of Environmental QualityRequires access

Automated Gas Chromatographic System for Rapid Analysis of the Atmospheric Trace Gases Methane, Carbon Dioxide, and Nitrous Oxide

Norman Loftfield, Heinz Flessa, J. Augustin, F. Beese

Open publisher page 358 citations

Abstract

Abstract To study the fluxes of the radiative active trace gases CH4, CO2, and N2O, a gas sampling and analytical device was developed. It is a useful tool for accurate gas sampling in the field and enables the subsequent fully automated analysis of the gas samples in the laboratory. The computer‐controlled analytical system consists of a gas chromatograph equipped with a flame ionization detector (FID), an electron capture detector (ECD), and a pressure‐controlled autosampler for 64 sample containers. The system automates sample injection, the analysis of CH4, CO2, and N2O in each sample and the subsequent evacuation of the sample containers. It is equipped with a second alternative sample inlet for manual syringe injection. This inlet is suitable for analyzing small volumes of gas samples (3 mL). The gas sampling system for use in the field consists of evacuated sample bottles (100 mL) with Teflon cocks combined with a small battery‐driven field sampler with a pressure sensor. This device enables an on‐site control of the vacuum integrity of the sample bottles during sampling and purging of the dead volumes between the sampler induction pipe and the sample container.

About this research paper

What this paper is about

Abstract To study the fluxes of the radiative active trace gases CH4, CO2, and N2O, a gas sampling and analytical device was developed. It is a useful tool for accurate gas sampling in the field and enables the subsequent fully automated analysis of the gas samples in the laboratory. The computer‐controlled analytical system consists of a gas chromatograph equipped with a flame ionization detector (FID), an electron capture detector (ECD), and a pressure‐controlled autosampler for 64 sample containers. The system automates sample injection, the analysis of CH4, CO2, and N2O in each sample and the subsequent evacuation of the sample containers. It is equipped with a second alternative sample inlet for manual syringe injection. This inlet is suitable for analyzing small volumes of gas samples (3 mL). The gas sampling system for use in the field consists of evacuated sample bottles (100 mL) with Teflon cocks combined with a small battery‐driven field sampler with a pressure sensor. This device enables an on‐site control of the vacuum integrity of the sample bottles during sampling and purging of the dead volumes between the sampler induction pipe and the sample container.

Why it matters

OpenAlex reports 358 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract To study the fluxes of the radiative active trace gases CH4, CO2, and N2O, a gas sampling and analytical device was developed. It is a useful tool for accurate gas sampling in the field and enables the subsequent fully automated analysis of the gas samples in the laboratory. The computer‐controlled analytical system consists of a gas chromatograph equipped with a flame ionization detector (FID), an electron capture detector (ECD), and a pressure‐controlled autosampler for 64 sample containers. The system automates sample injection, the analysis of CH4, CO2, and N2O in each sample and the subsequent evacuation of the sample containers. It is equipped with a second alternative sample inlet for manual syringe injection. This inlet is suitable for analyzing small volumes of gas samples (3 mL). The gas sampling system for use in the field consists of evacuated sample bottles (100 mL) with Teflon cocks combined with a small battery‐driven field sampler with a pressure sensor. This device enables an on‐site control of the vacuum integrity of the sample bottles during sampling and purging of the dead volumes between the sampler induction pipe and the sample container.

Key concepts: Methane, Flame ionization detector, Carbon dioxide, Chemistry, Sampling (signal processing), Trace gas, Sample (material), Electron capture detector

Related papers

Back to paper searchBrowse research topicsOriginal source
Automated Gas Chromatographic System for Rapid Analysis of the Atmospheric Trace Gases Methane, Carbon Dioxide, and Nitrous Oxide — Research Paper | ScholarLens