Personal Exposure to Polybrominated Diphenyl Ethers (PBDEs) in Residential Indoor Air
Joseph Gardner Allen, Michael D. McClean, Heather M. Stapleton, Jessica W. Nelson, Thomas F. Webster
Abstract
Joseph Gardner Allen, Michael D. McClean, Heather M. Stapleton, Jessica W. Nelson, Thomas F. Webster
Abstract
We used personal air samplers to measure indoor air exposure to polybrominated diphenyl ethers (PBDEs) for 20 residents of the Greater Boston Area (Massachusetts). Area air measures were simultaneously collected from two rooms in each participant's home. Total personal air concentrations (particulate + vapor) were 469 pg/m3 for non-209 BDEs and 174 pg/m3 for BDE 209, significantly higher than bedroom and main living room concentrations (p = 0.01). The ratio of personal air to room air increased from 1 for vapor-phase congeners to 4 for fully particulate-bound congeners, indicating a personal cloud effect. Bedroom and main living area air samples were moderately correlated for non-209 BDEs (r = 0.45, p = 0.045) and BDE 209 (r = 0.58, p = 0.008). Use of personal air concentrations increased estimates of inhalation exposure over those previously reported. Inhalation may account for up to 22% of the total BDE 209 exposure in U.S. adults.
OpenAlex reports 229 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We used personal air samplers to measure indoor air exposure to polybrominated diphenyl ethers (PBDEs) for 20 residents of the Greater Boston Area (Massachusetts). Area air measures were simultaneously collected from two rooms in each participant's home. Total personal air concentrations (particulate + vapor) were 469 pg/m3 for non-209 BDEs and 174 pg/m3 for BDE 209, significantly higher than bedroom and main living room concentrations (p = 0.01). The ratio of personal air to room air increased from 1 for vapor-phase congeners to 4 for fully particulate-bound congeners, indicating a personal cloud effect. Bedroom and main living area air samples were moderately correlated for non-209 BDEs (r = 0.45, p = 0.045) and BDE 209 (r = 0.58, p = 0.008). Use of personal air concentrations increased estimates of inhalation exposure over those previously reported. Inhalation may account for up to 22% of the total BDE 209 exposure in U.S. adults.
Key concepts: Polybrominated diphenyl ethers, Bedroom, Particulates, Environmental chemistry, Inhalation exposure, Indoor air, Environmental science, Polybrominated Biphenyls