Implementation--ASHRAE standard 90-75. Final report

Werner J. van der Meer

Open publisher page 0 citations

Abstract

Based on a study of meteorological conditions in New Mexico, the state was divided into 11 climatic zones, and building wall design conditions were determined for each zone. Using the concept of an Effective U Value, defined as the average heat transfer rate through a wall over an extended time, e.g., an entire season, 26 different wall types with various window combinations and color tones were designated as acceptable by ASHRAE Standard 90-75 building code. Also, 26 houses in the Albuquerque area were surveyed for actual energy consumption and computed energy use using both traditional and the Effective U Value computing methods. Calculations by the Effective U Value method were much closer to measured energy consumption. New Mexico has adopted an Energy Conservation Building Code and use of Effective U Values to determine whether wall constructions are in compliance with the code have promoted the code's implementation. (LCL)

About this research paper

What this paper is about

Based on a study of meteorological conditions in New Mexico, the state was divided into 11 climatic zones, and building wall design conditions were determined for each zone. Using the concept of an Effective U Value, defined as the average heat transfer rate through a wall over an extended time, e.g., an entire season, 26 different wall types with various window combinations and color tones were designated as acceptable by ASHRAE Standard 90-75 building code. Also, 26 houses in the Albuquerque area were surveyed for actual energy consumption and computed energy use using both traditional and the Effective U Value computing methods. Calculations by the Effective U Value method were much closer to measured energy consumption. New Mexico has adopted an Energy Conservation Building Code and use of Effective U Values to determine whether wall constructions are in compliance with the code have promoted the code's implementation. (LCL)

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Based on a study of meteorological conditions in New Mexico, the state was divided into 11 climatic zones, and building wall design conditions were determined for each zone. Using the concept of an Effective U Value, defined as the average heat transfer rate through a wall over an extended time, e.g., an entire season, 26 different wall types with various window combinations and color tones were designated as acceptable by ASHRAE Standard 90-75 building code. Also, 26 houses in the Albuquerque area were surveyed for actual energy consumption and computed energy use using both traditional and the Effective U Value computing methods. Calculations by the Effective U Value method were much closer to measured energy consumption. New Mexico has adopted an Energy Conservation Building Code and use of Effective U Values to determine whether wall constructions are in compliance with the code have promoted the code's implementation. (LCL)

Key concepts: ASHRAE 90.1, Building code, Energy consumption, Code (set theory), Environmental science, Meteorology, Energy conservation, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Implementation--ASHRAE standard 90-75. Final report — Research Paper | ScholarLens