2014Unpublished venueRequires access

ICMIEE-PI-14035410 000 Energy simulation to estimate building energy consumption using EnergyPlus

Jahangir Alam, Mohammad Ariful Islam, Biplob Kumar Biswas

Open publisher page 0 citations

Abstract

To achieve sustainable and green design, performance simulations are often used to verify these criteria and modify the design. The conventional approach of manual trial-and-error is too time-consuming to be practical. The evaluation of building energy consumption usually requires building energy profiles on month and category basis. EnergyPlus-Windows32-8.1.0.009, simulations were integrated to obtain this information but generating simulations requires a significant amount of experience, time, and effort to enter detailed building parameters. This paper presents a simple methodology to estimate source and site energy, where maximum energy requirement are 1485.14 MJ/m 2 and 447.6 MJ/m 2 ; respectively for D (mass type wall with attic) category within different categories (A-F) building. Moreover utility use per total floor area also calculated. Maximum U -factor with or without film are 0.512, 0.554 W/m 2 .K; respectively for wall of building. For one year max tariff charge is 63.5$ on electrical source energy consumption for D category building. In addition to summer and winter clothes maximum and minimum uncomfortable time are 436.25 (for D-category and 390.75 (for E-category) hours as annual. The methodology has been applied to hypothetical buildings placed in Jessore, Bangladesh.

About this research paper

What this paper is about

To achieve sustainable and green design, performance simulations are often used to verify these criteria and modify the design. The conventional approach of manual trial-and-error is too time-consuming to be practical. The evaluation of building energy consumption usually requires building energy profiles on month and category basis. EnergyPlus-Windows32-8.1.0.009, simulations were integrated to obtain this information but generating simulations requires a significant amount of experience, time, and effort to enter detailed building parameters. This paper presents a simple methodology to estimate source and site energy, where maximum energy requirement are 1485.14 MJ/m 2 and 447.6 MJ/m 2 ; respectively for D (mass type wall with attic) category within different categories (A-F) building. Moreover utility use per total floor area also calculated. Maximum U -factor with or without film are 0.512, 0.554 W/m 2 .K; respectively for wall of building. For one year max tariff charge is 63.5$ on electrical source energy consumption for D category building. In addition to summer and winter clothes maximum and minimum uncomfortable time are 436.25 (for D-category and 390.75 (for E-category) hours as annual. The methodology has been applied to hypothetical buildings placed in Jessore, Bangladesh.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To achieve sustainable and green design, performance simulations are often used to verify these criteria and modify the design. The conventional approach of manual trial-and-error is too time-consuming to be practical. The evaluation of building energy consumption usually requires building energy profiles on month and category basis. EnergyPlus-Windows32-8.1.0.009, simulations were integrated to obtain this information but generating simulations requires a significant amount of experience, time, and effort to enter detailed building parameters. This paper presents a simple methodology to estimate source and site energy, where maximum energy requirement are 1485.14 MJ/m 2 and 447.6 MJ/m 2 ; respectively for D (mass type wall with attic) category within different categories (A-F) building. Moreover utility use per total floor area also calculated. Maximum U -factor with or without film are 0.512, 0.554 W/m 2 .K; respectively for wall of building. For one year max tariff charge is 63.5$ on electrical source energy consumption for D category building. In addition to summer and winter clothes maximum and minimum uncomfortable time are 436.25 (for D-category and 390.75 (for E-category) hours as annual. The methodology has been applied to hypothetical buildings placed in Jessore, Bangladesh.

Key concepts: Energy consumption, Energy (signal processing), Consumption (sociology), Clothing, Mathematics, Architectural engineering, Computer science, Statistics