2000•Asia Pacific Journal of Speech Language and HearingRequires access

Comparison of hearing thresholds measured with supra-aural headphones and earphones fitted to custm earmoulds

Michelle R. Dean, Michelle S. Kornblum, Hugh J. McDermott

Open publisher page 0 citations

Abstract

An investigation to compare hearing threshold levels measured with headphones (THP) and button-type earphones (TEP) was performed with eight moderately-to-profoundly hearing-impaired adults. The earphone output was calibrated in this study by measuring the sound pressure level using an ear simulator (B and K Type 4157). The earphone threshold levels were combined with the reference equivalent threshold SP Ls for the ER -3A insert earphone (ANSI, 1989) to convert the earphone data to equivalent dB HL units. Differences in threshold levels for headphones and earphones (THP – TEP) were within 5 dB for frequencies between 125 Hz and 2000 Hz, except at 1414 Hz where it was +8.7dB. At 2828 and 4000 Hz, the differences were −10.4 and −19.6 dB, respectively. Random variance in measured threshold levels was comparable for earphones and headphones in the frequency range of 125–2828 Hz. The results of this study have established a set of correction figures enabling the calibration of hearing threshold levels measured via the Oticon AN1000 earphone into equivalent dB HL units. These data are now being used in a computer-assisted hearing-aid fitting procedure to improve the accuracy and reliability of hearing-aid fitting for hearing-impaired individuals, while eliminating the need to measure thresholds separately using an audiometer and headphones.

About this research paper

What this paper is about

An investigation to compare hearing threshold levels measured with headphones (THP) and button-type earphones (TEP) was performed with eight moderately-to-profoundly hearing-impaired adults. The earphone output was calibrated in this study by measuring the sound pressure level using an ear simulator (B and K Type 4157). The earphone threshold levels were combined with the reference equivalent threshold SP Ls for the ER -3A insert earphone (ANSI, 1989) to convert the earphone data to equivalent dB HL units. Differences in threshold levels for headphones and earphones (THP – TEP) were within 5 dB for frequencies between 125 Hz and 2000 Hz, except at 1414 Hz where it was +8.7dB. At 2828 and 4000 Hz, the differences were −10.4 and −19.6 dB, respectively. Random variance in measured threshold levels was comparable for earphones and headphones in the frequency range of 125–2828 Hz. The results of this study have established a set of correction figures enabling the calibration of hearing threshold levels measured via the Oticon AN1000 earphone into equivalent dB HL units. These data are now being used in a computer-assisted hearing-aid fitting procedure to improve the accuracy and reliability of hearing-aid fitting for hearing-impaired individuals, while eliminating the need to measure thresholds separately using an audiometer and headphones.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An investigation to compare hearing threshold levels measured with headphones (THP) and button-type earphones (TEP) was performed with eight moderately-to-profoundly hearing-impaired adults. The earphone output was calibrated in this study by measuring the sound pressure level using an ear simulator (B and K Type 4157). The earphone threshold levels were combined with the reference equivalent threshold SP Ls for the ER -3A insert earphone (ANSI, 1989) to convert the earphone data to equivalent dB HL units. Differences in threshold levels for headphones and earphones (THP – TEP) were within 5 dB for frequencies between 125 Hz and 2000 Hz, except at 1414 Hz where it was +8.7dB. At 2828 and 4000 Hz, the differences were −10.4 and −19.6 dB, respectively. Random variance in measured threshold levels was comparable for earphones and headphones in the frequency range of 125–2828 Hz. The results of this study have established a set of correction figures enabling the calibration of hearing threshold levels measured via the Oticon AN1000 earphone into equivalent dB HL units. These data are now being used in a computer-assisted hearing-aid fitting procedure to improve the accuracy and reliability of hearing-aid fitting for hearing-impaired individuals, while eliminating the need to measure thresholds separately using an audiometer and headphones.

Key concepts: Headphones, Audiometer, Absolute threshold of hearing, Audiology, Hearing aid, Acoustics, Calibration, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of hearing thresholds measured with supra-aural headphones and earphones fitted to custm earmoulds — Research Paper | ScholarLens