1999•LuminescenceRequires access

Chemiluminescent detection of catecholamines by generation of hydrogen peroxide with imidazole

Osamu Nozaki, Toshinao Iwaeda, Hiroyuki Moriyama, Yoshio Kato

Open publisher page 29 citations

Abstract

A novel detection method for catecholamines using imidazole was investigated using a chemiluminescence coupled flow injection system. Imidazole catalysed decomposition of catecholamines to generate hydrogen peroxide, then the hydrogen peroxide was detected by chemiluminescence. The optimal condition for generation of hydrogen peroxide from a catecholamine was to incubate the catecholamines (53 pmol) in an imidazole solution (50 mmol/L, pH 9.0, 1.0 mL) at 60 degrees C for 30 min. Peroxide-was detected by peroxyoxalate chemiluminescence, and the rank order of the light emission intensities was as follows; dopamine (100%) >epinephrine (78%) >L-DOPA (62%) >norepinephrine (58%) >deoxyepinephrine (51%) >isoproterenol (43%) >dihydroxybenzylamine (25%). The light intensities of the reaction mixtures (corresponding to 1.06 pmol catecholamines) varied depending on the chemiluminescence (CL) detection reaction, and the rank order of the light intensity was as follows; luminol CL catalysed with horseradish peroxidase (HRP) (371%) >peroxyoxalate chemiluminescence (100%) >luminol CL catalysed with ferrycyanide (62%) >lucigenin CL (15%) >pyrogallol CL (0.8%) >purpurogallin CL (0.4%) >luminol CL (0.3%). The luminol CL reaction catalysed by HRP is recommended for the detection of peroxide in this method for catecholamines.

About this research paper

What this paper is about

A novel detection method for catecholamines using imidazole was investigated using a chemiluminescence coupled flow injection system. Imidazole catalysed decomposition of catecholamines to generate hydrogen peroxide, then the hydrogen peroxide was detected by chemiluminescence. The optimal condition for generation of hydrogen peroxide from a catecholamine was to incubate the catecholamines (53 pmol) in an imidazole solution (50 mmol/L, pH 9.0, 1.0 mL) at 60 degrees C for 30 min. Peroxide-was detected by peroxyoxalate chemiluminescence, and the rank order of the light emission intensities was as follows; dopamine (100%) >epinephrine (78%) >L-DOPA (62%) >norepinephrine (58%) >deoxyepinephrine (51%) >isoproterenol (43%) >dihydroxybenzylamine (25%). The light intensities of the reaction mixtures (corresponding to 1.06 pmol catecholamines) varied depending on the chemiluminescence (CL) detection reaction, and the rank order of the light intensity was as follows; luminol CL catalysed with horseradish peroxidase (HRP) (371%) >peroxyoxalate chemiluminescence (100%) >luminol CL catalysed with ferrycyanide (62%) >lucigenin CL (15%) >pyrogallol CL (0.8%) >purpurogallin CL (0.4%) >luminol CL (0.3%). The luminol CL reaction catalysed by HRP is recommended for the detection of peroxide in this method for catecholamines.

Why it matters

OpenAlex reports 29 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel detection method for catecholamines using imidazole was investigated using a chemiluminescence coupled flow injection system. Imidazole catalysed decomposition of catecholamines to generate hydrogen peroxide, then the hydrogen peroxide was detected by chemiluminescence. The optimal condition for generation of hydrogen peroxide from a catecholamine was to incubate the catecholamines (53 pmol) in an imidazole solution (50 mmol/L, pH 9.0, 1.0 mL) at 60 degrees C for 30 min. Peroxide-was detected by peroxyoxalate chemiluminescence, and the rank order of the light emission intensities was as follows; dopamine (100%) >epinephrine (78%) >L-DOPA (62%) >norepinephrine (58%) >deoxyepinephrine (51%) >isoproterenol (43%) >dihydroxybenzylamine (25%). The light intensities of the reaction mixtures (corresponding to 1.06 pmol catecholamines) varied depending on the chemiluminescence (CL) detection reaction, and the rank order of the light intensity was as follows; luminol CL catalysed with horseradish peroxidase (HRP) (371%) >peroxyoxalate chemiluminescence (100%) >luminol CL catalysed with ferrycyanide (62%) >lucigenin CL (15%) >pyrogallol CL (0.8%) >purpurogallin CL (0.4%) >luminol CL (0.3%). The luminol CL reaction catalysed by HRP is recommended for the detection of peroxide in this method for catecholamines.

Key concepts: Chemiluminescence, Peroxyoxalate, Luminol, Hydrogen peroxide, Chemistry, Horseradish peroxidase, Peroxide, Pyrogallol

Related papers

Back to paper searchBrowse research topicsOriginal source
Chemiluminescent detection of catecholamines by generation of hydrogen peroxide with imidazole — Research Paper | ScholarLens