Determination of trace amounts of silver(I) in the presence of an activator with a kinetic method
Shahryar Abbasi, Hadi Barzegaramiri, Abbas Farmany
Abstract
Shahryar Abbasi, Hadi Barzegaramiri, Abbas Farmany
Abstract
Abstract A simple and sensitive kinetic‐spectrophotometric method was developed for the determination of trace amounts of silver, based on its catalytic effect on the oxidation of azocarmine G by peroxydisulfate in sulfuric acid medium and at 30 °C in the presence of 1,10‐phenantroline as activator. The absorbance was measured at 525 nm with the fixed‐time method. The optimization of the operating conditions regarding concentrations of the reagents, temperature, ionic strength, and interferences was also investigated. The calibration curve is linear over the concentration range 0.3–50.0 ng·ml −1 of silver with good precision and accuracy, and the detection limit is down to 0.125 ng·ml −1 . The relative standard deviation for a standard solution of 25.0 ng·ml −1 of silver is 1.36 % ( n = 10). The proposed method proves to be highly sensitive, selective, and relatively rapid for the assay of silver at low‐level range of 0.3–50.0 ng·ml −1 without any pre‐concentration and separation step. The method was applied for the determination of silver in river water and white photographic film. The analytic results of the real samples are in excellent agreement with atomic absorption spectrometry analysis. The analytical results obtained are satisfactory.
OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract A simple and sensitive kinetic‐spectrophotometric method was developed for the determination of trace amounts of silver, based on its catalytic effect on the oxidation of azocarmine G by peroxydisulfate in sulfuric acid medium and at 30 °C in the presence of 1,10‐phenantroline as activator. The absorbance was measured at 525 nm with the fixed‐time method. The optimization of the operating conditions regarding concentrations of the reagents, temperature, ionic strength, and interferences was also investigated. The calibration curve is linear over the concentration range 0.3–50.0 ng·ml −1 of silver with good precision and accuracy, and the detection limit is down to 0.125 ng·ml −1 . The relative standard deviation for a standard solution of 25.0 ng·ml −1 of silver is 1.36 % ( n = 10). The proposed method proves to be highly sensitive, selective, and relatively rapid for the assay of silver at low‐level range of 0.3–50.0 ng·ml −1 without any pre‐concentration and separation step. The method was applied for the determination of silver in river water and white photographic film. The analytic results of the real samples are in excellent agreement with atomic absorption spectrometry analysis. The analytical results obtained are satisfactory.
Key concepts: Peroxydisulfate, Absorbance, Reagent, Detection limit, Calibration curve, Analytical Chemistry (journal), Ionic strength, Trace Amounts