High-intensity nanosecond white-light source using a commercially available Xe arc lamp
Shin Itami, Tsutomu Araki
Abstract
Shin Itami, Tsutomu Araki
Abstract
We have developed an intense, white emission spectrum, nanosecond pulsed light source using a commercially available Xe short-arc lamp. This light source is simple in construction, physically compact and easy to operate. In the previous study, we have applied 35 - 75 W type lamp as the light source. In the present study we applied two 150 W type Xe-arc lamps. Because the electrode gap of the 150 W lamp is wider than that of 35 - 75 W type, applied voltage higher than 16 kV is required for the pulsed operation of the 150 W lamp. Intense light pulses as large as 140 W (peak power) of 15.2 ns duration (FWHM) were obtained repetitively from the Xe lamps. This lamp produced broadband emission spectrum (250 - 650 nm) according to discharge of Xe gas. Present lamp operation is free-running type, but it is possible to control the discharge timing using a thyratron. The intense emission characteristic can be utilized not only as the excitation light source in time-resolved fluorometry but also as the stroboscopic illumination source in high-speed photograph.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We have developed an intense, white emission spectrum, nanosecond pulsed light source using a commercially available Xe short-arc lamp. This light source is simple in construction, physically compact and easy to operate. In the previous study, we have applied 35 - 75 W type lamp as the light source. In the present study we applied two 150 W type Xe-arc lamps. Because the electrode gap of the 150 W lamp is wider than that of 35 - 75 W type, applied voltage higher than 16 kV is required for the pulsed operation of the 150 W lamp. Intense light pulses as large as 140 W (peak power) of 15.2 ns duration (FWHM) were obtained repetitively from the Xe lamps. This lamp produced broadband emission spectrum (250 - 650 nm) according to discharge of Xe gas. Present lamp operation is free-running type, but it is possible to control the discharge timing using a thyratron. The intense emission characteristic can be utilized not only as the excitation light source in time-resolved fluorometry but also as the stroboscopic illumination source in high-speed photograph.
Key concepts: Arc lamp, Gas-discharge lamp, Nanosecond, Thyratron, Incandescent light bulb, Hollow-cathode lamp, Optics, Fluorescent lamp