1997RadiologyRequires access

Mammographic findings after stereotactic 14-gauge vacuum biopsy.

Laura Liberman, Lucy E. Hann, D. David Dershaw, Elizabeth A. Morris, A F Abramson, Peter Rosen

Open publisher page 61 citations

Abstract

PURPOSE: To evaluate mammographic findings after stereotactic 14-gauge vacuum biopsy. MATERIALS AND METHODS: Retrospective review was performed of results at stereotactic 14-gauge vacuum biopsy in 108 lesions in 100 women. The median number of specimens obtained per lesion was 12 (mean, 14; range, 1-50). In all cases, mammography was performed immediately after vacuum biopsy. Pre- and postbiopsy mammograms were reviewed. RESULTS: Postbiopsy mammograms depicted air at the biopsy site in 78 (72%) of 108 lesions and hematoma in 65 (60%) of 108 lesions. Of 55 lesions depicted as calcifications, postbiopsy mammograms depicted a decrease in the number of calcifications in 45 (82%), including nine cases in which all calcifications were removed. No residual lesion was identified on postbiopsy mammograms in 14 (13%) of 108 lesions; 11 (58%) of 19 mammographic lesions that measured 0.5 cm or less in maximal dimension were completely removed. Nineteen patients underwent a needle localization procedure, at a median 14 days (range, 6-51 days) after vacuum biopsy. In one patient a hematoma was depicted at mammography 10 days after biopsy; in the remaining 18 (95%) patients, mammograms obtained during needle localization depicted no hematoma or air. CONCLUSION: Air and hematoma were often present on mammograms immediately after stereotactic vacuum biopsy, but these changes resolved rapidly. Stereotactic vacuum biopsy provided wide sampling of calcifications and allowed complete removal of the mammographic lesion in some cases.

About this research paper

What this paper is about

PURPOSE: To evaluate mammographic findings after stereotactic 14-gauge vacuum biopsy. MATERIALS AND METHODS: Retrospective review was performed of results at stereotactic 14-gauge vacuum biopsy in 108 lesions in 100 women. The median number of specimens obtained per lesion was 12 (mean, 14; range, 1-50). In all cases, mammography was performed immediately after vacuum biopsy. Pre- and postbiopsy mammograms were reviewed. RESULTS: Postbiopsy mammograms depicted air at the biopsy site in 78 (72%) of 108 lesions and hematoma in 65 (60%) of 108 lesions. Of 55 lesions depicted as calcifications, postbiopsy mammograms depicted a decrease in the number of calcifications in 45 (82%), including nine cases in which all calcifications were removed. No residual lesion was identified on postbiopsy mammograms in 14 (13%) of 108 lesions; 11 (58%) of 19 mammographic lesions that measured 0.5 cm or less in maximal dimension were completely removed. Nineteen patients underwent a needle localization procedure, at a median 14 days (range, 6-51 days) after vacuum biopsy. In one patient a hematoma was depicted at mammography 10 days after biopsy; in the remaining 18 (95%) patients, mammograms obtained during needle localization depicted no hematoma or air. CONCLUSION: Air and hematoma were often present on mammograms immediately after stereotactic vacuum biopsy, but these changes resolved rapidly. Stereotactic vacuum biopsy provided wide sampling of calcifications and allowed complete removal of the mammographic lesion in some cases.

Why it matters

OpenAlex reports 61 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To evaluate mammographic findings after stereotactic 14-gauge vacuum biopsy. MATERIALS AND METHODS: Retrospective review was performed of results at stereotactic 14-gauge vacuum biopsy in 108 lesions in 100 women. The median number of specimens obtained per lesion was 12 (mean, 14; range, 1-50). In all cases, mammography was performed immediately after vacuum biopsy. Pre- and postbiopsy mammograms were reviewed. RESULTS: Postbiopsy mammograms depicted air at the biopsy site in 78 (72%) of 108 lesions and hematoma in 65 (60%) of 108 lesions. Of 55 lesions depicted as calcifications, postbiopsy mammograms depicted a decrease in the number of calcifications in 45 (82%), including nine cases in which all calcifications were removed. No residual lesion was identified on postbiopsy mammograms in 14 (13%) of 108 lesions; 11 (58%) of 19 mammographic lesions that measured 0.5 cm or less in maximal dimension were completely removed. Nineteen patients underwent a needle localization procedure, at a median 14 days (range, 6-51 days) after vacuum biopsy. In one patient a hematoma was depicted at mammography 10 days after biopsy; in the remaining 18 (95%) patients, mammograms obtained during needle localization depicted no hematoma or air. CONCLUSION: Air and hematoma were often present on mammograms immediately after stereotactic vacuum biopsy, but these changes resolved rapidly. Stereotactic vacuum biopsy provided wide sampling of calcifications and allowed complete removal of the mammographic lesion in some cases.

Key concepts: Medicine, Stereotactic biopsy, Biopsy, Breast biopsy, Mammography, Radiology, Lesion, Hematoma

Related papers

Back to paper searchBrowse research topicsOriginal source
Mammographic findings after stereotactic 14-gauge vacuum biopsy. — Research Paper | ScholarLens