2008Acta RadiologicaRequires access

Use of Fogarty Catheter to Limit Hemorrhage and Hematoma after Vacuum-Assisted Breast Biopsy

George Zografos, Flora Zagouri, Theodoros Ν. Sergentanis, Dimitra Koulocheri, Nikolaos V. Michalopoulos, Chris Tsigris, John Bramis, Ilias P. Gomatos

Open publisher page 5 citations

Abstract

A 42-year-old woman underwent vacuum-assisted breast biopsy (VABB, 11G) due to a nonpalpable, BI-RADS 4A lesion without microcalcifications. During the procedure, an extraordinarily large amount of blood was lost. In an attempt to stop the hemorrhage and limit the imminent hematoma, a thin intravascular Fogarty catheter was inserted adjacent to the VABB probe (through the same incision). The catheter was maintained in its position for 2 days. At clinical examination 9 days after VABB, no hematoma was present. The use of a Fogarty catheter seems capable of limiting any severe bleeding after VABB and may also possibly prevent subsequent hematoma formation.

About this research paper

What this paper is about

A 42-year-old woman underwent vacuum-assisted breast biopsy (VABB, 11G) due to a nonpalpable, BI-RADS 4A lesion without microcalcifications. During the procedure, an extraordinarily large amount of blood was lost. In an attempt to stop the hemorrhage and limit the imminent hematoma, a thin intravascular Fogarty catheter was inserted adjacent to the VABB probe (through the same incision). The catheter was maintained in its position for 2 days. At clinical examination 9 days after VABB, no hematoma was present. The use of a Fogarty catheter seems capable of limiting any severe bleeding after VABB and may also possibly prevent subsequent hematoma formation.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A 42-year-old woman underwent vacuum-assisted breast biopsy (VABB, 11G) due to a nonpalpable, BI-RADS 4A lesion without microcalcifications. During the procedure, an extraordinarily large amount of blood was lost. In an attempt to stop the hemorrhage and limit the imminent hematoma, a thin intravascular Fogarty catheter was inserted adjacent to the VABB probe (through the same incision). The catheter was maintained in its position for 2 days. At clinical examination 9 days after VABB, no hematoma was present. The use of a Fogarty catheter seems capable of limiting any severe bleeding after VABB and may also possibly prevent subsequent hematoma formation.

Key concepts: Medicine, Hematoma, Breast biopsy, Catheter, Radiology, Biopsy, Limiting, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Use of Fogarty Catheter to Limit Hemorrhage and Hematoma after Vacuum-Assisted Breast Biopsy — Research Paper | ScholarLens