2002•Catheterization and Cardiovascular InterventionsRequires access

Comparison of the self‐expanding Radius stent and the balloon‐expandable Multilink stent for elective treatment of coronary stenoses: A serial analysis by intravascular ultrasound

Zaixin Yu, Hideo Tamai, Eisho Kyo, Kunihiko Kosuga, Tatsuhiko Hata, Masaharu Okada, Takuji Nakamura, Hidenori Komori, Takafumi Tsuji, Shinsaku Takeda, Seiichiro Motohara, Hiromu Uehata

Open publisher page 20 citations

Abstract

We compared the outcome of the self-expanding Radius stent and the balloon-expandable Multilink stent serially by angiography and intravascular ultrasound. Successful stent deployment was achieved in 66 lesions of 56 stable angina patients (34 lesions with Radius stents and 32 lesions with Multilink stents). At follow-up, there were no significant differences in minimal lumen diameter or percent diameter stenosis between the groups, nor in restenosis rates, although the Radius stent group rate was slightly lower (23.5% vs. 31.3%). In the Radius stent group, stent cross-sectional area (CSA) increased gradually after implantation until the 6-month follow-up (8.37 +/- 1.83 to 10.16 +/- 2.59 mm(2); n = 15), giving a larger CSA (P = 0.03) than the Multilink stent group, which decreased (9.00 +/- 2.05 to 8.27 +/- 2.15 mm(2); n = 17). The lumen CSA was also slightly larger (6.82 +/- 3.06 vs. 5.84 +/- 1.85 mm(2); P = 0.29) in the Radius stent group. These findings indicated that the Radius stent enlarged progressively after implantation, which might be useful for prevention of restenosis.

About this research paper

What this paper is about

We compared the outcome of the self-expanding Radius stent and the balloon-expandable Multilink stent serially by angiography and intravascular ultrasound. Successful stent deployment was achieved in 66 lesions of 56 stable angina patients (34 lesions with Radius stents and 32 lesions with Multilink stents). At follow-up, there were no significant differences in minimal lumen diameter or percent diameter stenosis between the groups, nor in restenosis rates, although the Radius stent group rate was slightly lower (23.5% vs. 31.3%). In the Radius stent group, stent cross-sectional area (CSA) increased gradually after implantation until the 6-month follow-up (8.37 +/- 1.83 to 10.16 +/- 2.59 mm(2); n = 15), giving a larger CSA (P = 0.03) than the Multilink stent group, which decreased (9.00 +/- 2.05 to 8.27 +/- 2.15 mm(2); n = 17). The lumen CSA was also slightly larger (6.82 +/- 3.06 vs. 5.84 +/- 1.85 mm(2); P = 0.29) in the Radius stent group. These findings indicated that the Radius stent enlarged progressively after implantation, which might be useful for prevention of restenosis.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We compared the outcome of the self-expanding Radius stent and the balloon-expandable Multilink stent serially by angiography and intravascular ultrasound. Successful stent deployment was achieved in 66 lesions of 56 stable angina patients (34 lesions with Radius stents and 32 lesions with Multilink stents). At follow-up, there were no significant differences in minimal lumen diameter or percent diameter stenosis between the groups, nor in restenosis rates, although the Radius stent group rate was slightly lower (23.5% vs. 31.3%). In the Radius stent group, stent cross-sectional area (CSA) increased gradually after implantation until the 6-month follow-up (8.37 +/- 1.83 to 10.16 +/- 2.59 mm(2); n = 15), giving a larger CSA (P = 0.03) than the Multilink stent group, which decreased (9.00 +/- 2.05 to 8.27 +/- 2.15 mm(2); n = 17). The lumen CSA was also slightly larger (6.82 +/- 3.06 vs. 5.84 +/- 1.85 mm(2); P = 0.29) in the Radius stent group. These findings indicated that the Radius stent enlarged progressively after implantation, which might be useful for prevention of restenosis.

Key concepts: Medicine, Stent, Intravascular ultrasound, Restenosis, Lumen (anatomy), Balloon, Stenosis, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of the self‐expanding Radius stent and the balloon‐expandable Multilink stent for elective treatment of coronary stenoses: A serial analysis by intravascular ultrasound — Research Paper | ScholarLens