2012•Journal of the Serbian Chemical SocietyOpen access

Genetic algorithm-based wavelength selection in multicomponent spectrophotometric determination by PLS: Application on sulfamethoxazole and trimethoprim mixture in bovine milk

Mohammad Hadi Givianrad, Mohammad Saber Tehrani, Saber Zarin

Open full text 9 citations

Abstract

The simultaneous determination of sulfamethoxazole (SMX) and trimethoprim (TMP) mixtures in bovine milk by spectrophotometric method is a difficult problem in analytical chemistry, due to spectral interferences. By means of multivariate calibration methods, such as partial least square (PLS) regression, it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Genetic algorithm (GA) is a suitable method for selecting wavelengths for PLS calibration of mixtures with almost identical spectra without loss of prediction capacity using the spectrophotometric method. In this study, the calibration model based on absorption spectra in the 200-400 nm range for 25 different mixtures of SMX and TMP Calibration matrices were formed form samples containing 0.25-20 and 0.3-21 ?g mL-1 for SMX and TMP, at pH=10, respectively. The root mean squared error of deviation (RMSED) for SMX and TMP with PLS and genetic algorithm partial least square (GAPLS) were 0.242, 0.066 ?gmL-1 and 0.074, 0.027 ?g mL-1, respectively. This procedure was allowed the simultaneous determination of SMX and TMP in synthetic and real samples and good reliability of the determination was proved.

Open-access reader

About this research paper

What this paper is about

The simultaneous determination of sulfamethoxazole (SMX) and trimethoprim (TMP) mixtures in bovine milk by spectrophotometric method is a difficult problem in analytical chemistry, due to spectral interferences. By means of multivariate calibration methods, such as partial least square (PLS) regression, it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Genetic algorithm (GA) is a suitable method for selecting wavelengths for PLS calibration of mixtures with almost identical spectra without loss of prediction capacity using the spectrophotometric method. In this study, the calibration model based on absorption spectra in the 200-400 nm range for 25 different mixtures of SMX and TMP Calibration matrices were formed form samples containing 0.25-20 and 0.3-21 ?g mL-1 for SMX and TMP, at pH=10, respectively. The root mean squared error of deviation (RMSED) for SMX and TMP with PLS and genetic algorithm partial least square (GAPLS) were 0.242, 0.066 ?gmL-1 and 0.074, 0.027 ?g mL-1, respectively. This procedure was allowed the simultaneous determination of SMX and TMP in synthetic and real samples and good reliability of the determination was proved.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The simultaneous determination of sulfamethoxazole (SMX) and trimethoprim (TMP) mixtures in bovine milk by spectrophotometric method is a difficult problem in analytical chemistry, due to spectral interferences. By means of multivariate calibration methods, such as partial least square (PLS) regression, it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Genetic algorithm (GA) is a suitable method for selecting wavelengths for PLS calibration of mixtures with almost identical spectra without loss of prediction capacity using the spectrophotometric method. In this study, the calibration model based on absorption spectra in the 200-400 nm range for 25 different mixtures of SMX and TMP Calibration matrices were formed form samples containing 0.25-20 and 0.3-21 ?g mL-1 for SMX and TMP, at pH=10, respectively. The root mean squared error of deviation (RMSED) for SMX and TMP with PLS and genetic algorithm partial least square (GAPLS) were 0.242, 0.066 ?gmL-1 and 0.074, 0.027 ?g mL-1, respectively. This procedure was allowed the simultaneous determination of SMX and TMP in synthetic and real samples and good reliability of the determination was proved.

Key concepts: Calibration, Partial least squares regression, Trimethoprim, Mean squared error, Chromatography, Chemistry, Analytical Chemistry (journal), Root mean square

Related papers

Back to paper searchBrowse research topicsOriginal source
Genetic algorithm-based wavelength selection in multicomponent spectrophotometric determination by PLS: Application on sulfamethoxazole and trimethoprim mixture in bovine milk — Research Paper | ScholarLens