Transscleral red‐laser cyclophotocoagulation combined with limited anterior retinal cryocoagulation in neovascular glaucoma
Virpi Raivio, Ilkka J. R. Immonen, Päivi M. Puska
Abstract
Open-access reader
Virpi Raivio, Ilkka J. R. Immonen, Päivi M. Puska
Abstract
Open-access reader
PURPOSE: To evaluate transscleral contact red-laser cyclophotocoagulation (CPC), using a visible red 647-nm krypton or 670-nm diode laser and limited transscleral anterior retinal cryocoagulation in neovascular glaucoma. METHODS: In a retrospective case series, 35 eyes of 35 consecutive patients treated during a period of 6 years were included in the study. Inclusion was dependent on follow-up of at least 1 month. Patients who had undergone previous cyclodestructive procedures and patients who received an additional glaucoma operation in conjunction with CPC were excluded. In the combined procedure, the power per CPC application was 370-450 mW and exposure time was 10 seconds. One to two rows of cryoapplications were given to 360 degrees of the anterior retina. RESULTS: The success rate in terms of intraocular pressure (IOP of 8-21 mmHg or a decrease in IOP > 30%) was 89% at the last follow-up (17 +/- 15 months). Iris neovascularization regressed in 51% of eyes. Hypotonia developed in one (3%) eye (IOP of 5 mmHg). No cases of phthisis bulbi were seen. Visual acuity (VA) declined in 49% of eyes. CONCLUSIONS: A combination of transscleral contact red-laser CPC with limited anterior retinal cryocoagulation is efficient in lowering IOP in neovascular glaucoma and is well tolerated. During follow-up, a decrease in VA occurs in a significant proportion of patients.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: To evaluate transscleral contact red-laser cyclophotocoagulation (CPC), using a visible red 647-nm krypton or 670-nm diode laser and limited transscleral anterior retinal cryocoagulation in neovascular glaucoma. METHODS: In a retrospective case series, 35 eyes of 35 consecutive patients treated during a period of 6 years were included in the study. Inclusion was dependent on follow-up of at least 1 month. Patients who had undergone previous cyclodestructive procedures and patients who received an additional glaucoma operation in conjunction with CPC were excluded. In the combined procedure, the power per CPC application was 370-450 mW and exposure time was 10 seconds. One to two rows of cryoapplications were given to 360 degrees of the anterior retina. RESULTS: The success rate in terms of intraocular pressure (IOP of 8-21 mmHg or a decrease in IOP > 30%) was 89% at the last follow-up (17 +/- 15 months). Iris neovascularization regressed in 51% of eyes. Hypotonia developed in one (3%) eye (IOP of 5 mmHg). No cases of phthisis bulbi were seen. Visual acuity (VA) declined in 49% of eyes. CONCLUSIONS: A combination of transscleral contact red-laser CPC with limited anterior retinal cryocoagulation is efficient in lowering IOP in neovascular glaucoma and is well tolerated. During follow-up, a decrease in VA occurs in a significant proportion of patients.
Key concepts: Medicine, Phthisis bulbi, Ophthalmology, Intraocular pressure, Neovascular glaucoma, Visual acuity, Glaucoma, Retinal