2002Annals of Clinical Biochemistry International Journal of Laboratory MedicineRequires access

Evaluation of a sandwich enzyme-linked immunosorbent assay for the measurement of serum heart fatty acid-binding protein

Franca Pagani, R Bonora, Graziella Bonetti, Mauro Panteghini

Open publisher page 34 citations

Abstract

BACKGROUND: We evaluated the sandwich enzyme-linked immunosorbent assay (ELISA) MARKIT-M for the determination of heart fatty-acid-binding protein (H-FABP). RESULTS AND CONCLUSIONS: The between-run coefficient of variation of this assay was <3.9 and it showed good correlation with a previously established ELISA method. The upper reference limit in 30 healthy individuals was 6.1 microg/L. Admission serum H-FABP was evaluated against myoglobin in 41 patients with suspected myocardial infarction (onset of symptoms < or = 5 h). H-FABP showed the same diagnostic efficiency as myoglobin [area (standard error) under the receiver operating characteristic curve: 0.798 (0.079) for H-FABP, 0.771 (0.085) for myoglobin, P = 0.55]. However, using the upper reference limit as decision cut-off, the sensitivity for H-FABP [91%; 95% confidence interval (CI): 76-98%] was significantly (P = 0.019) higher than that of myoglobin (65%; 95% CI: 47-80%).

About this research paper

What this paper is about

BACKGROUND: We evaluated the sandwich enzyme-linked immunosorbent assay (ELISA) MARKIT-M for the determination of heart fatty-acid-binding protein (H-FABP). RESULTS AND CONCLUSIONS: The between-run coefficient of variation of this assay was <3.9 and it showed good correlation with a previously established ELISA method. The upper reference limit in 30 healthy individuals was 6.1 microg/L. Admission serum H-FABP was evaluated against myoglobin in 41 patients with suspected myocardial infarction (onset of symptoms < or = 5 h). H-FABP showed the same diagnostic efficiency as myoglobin [area (standard error) under the receiver operating characteristic curve: 0.798 (0.079) for H-FABP, 0.771 (0.085) for myoglobin, P = 0.55]. However, using the upper reference limit as decision cut-off, the sensitivity for H-FABP [91%; 95% confidence interval (CI): 76-98%] was significantly (P = 0.019) higher than that of myoglobin (65%; 95% CI: 47-80%).

Why it matters

OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: We evaluated the sandwich enzyme-linked immunosorbent assay (ELISA) MARKIT-M for the determination of heart fatty-acid-binding protein (H-FABP). RESULTS AND CONCLUSIONS: The between-run coefficient of variation of this assay was <3.9 and it showed good correlation with a previously established ELISA method. The upper reference limit in 30 healthy individuals was 6.1 microg/L. Admission serum H-FABP was evaluated against myoglobin in 41 patients with suspected myocardial infarction (onset of symptoms < or = 5 h). H-FABP showed the same diagnostic efficiency as myoglobin [area (standard error) under the receiver operating characteristic curve: 0.798 (0.079) for H-FABP, 0.771 (0.085) for myoglobin, P = 0.55]. However, using the upper reference limit as decision cut-off, the sensitivity for H-FABP [91%; 95% confidence interval (CI): 76-98%] was significantly (P = 0.019) higher than that of myoglobin (65%; 95% CI: 47-80%).

Key concepts: Myoglobin, Heart-type fatty acid binding protein, Receiver operating characteristic, Fatty acid-binding protein, Confidence interval, Detection limit, Medicine, Myocardial infarction

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of a sandwich enzyme-linked immunosorbent assay for the measurement of serum heart fatty acid-binding protein — Research Paper | ScholarLens