Evaluation of a sandwich enzyme-linked immunosorbent assay for the measurement of serum heart fatty acid-binding protein
Franca Pagani, R Bonora, Graziella Bonetti, Mauro Panteghini
Abstract
Franca Pagani, R Bonora, Graziella Bonetti, Mauro Panteghini
Abstract
BACKGROUND: We evaluated the sandwich enzyme-linked immunosorbent assay (ELISA) MARKIT-M for the determination of heart fatty-acid-binding protein (H-FABP). RESULTS AND CONCLUSIONS: The between-run coefficient of variation of this assay was <3.9 and it showed good correlation with a previously established ELISA method. The upper reference limit in 30 healthy individuals was 6.1 microg/L. Admission serum H-FABP was evaluated against myoglobin in 41 patients with suspected myocardial infarction (onset of symptoms < or = 5 h). H-FABP showed the same diagnostic efficiency as myoglobin [area (standard error) under the receiver operating characteristic curve: 0.798 (0.079) for H-FABP, 0.771 (0.085) for myoglobin, P = 0.55]. However, using the upper reference limit as decision cut-off, the sensitivity for H-FABP [91%; 95% confidence interval (CI): 76-98%] was significantly (P = 0.019) higher than that of myoglobin (65%; 95% CI: 47-80%).
OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND: We evaluated the sandwich enzyme-linked immunosorbent assay (ELISA) MARKIT-M for the determination of heart fatty-acid-binding protein (H-FABP). RESULTS AND CONCLUSIONS: The between-run coefficient of variation of this assay was <3.9 and it showed good correlation with a previously established ELISA method. The upper reference limit in 30 healthy individuals was 6.1 microg/L. Admission serum H-FABP was evaluated against myoglobin in 41 patients with suspected myocardial infarction (onset of symptoms < or = 5 h). H-FABP showed the same diagnostic efficiency as myoglobin [area (standard error) under the receiver operating characteristic curve: 0.798 (0.079) for H-FABP, 0.771 (0.085) for myoglobin, P = 0.55]. However, using the upper reference limit as decision cut-off, the sensitivity for H-FABP [91%; 95% confidence interval (CI): 76-98%] was significantly (P = 0.019) higher than that of myoglobin (65%; 95% CI: 47-80%).
Key concepts: Myoglobin, Heart-type fatty acid binding protein, Receiver operating characteristic, Fatty acid-binding protein, Confidence interval, Detection limit, Medicine, Myocardial infarction