1957Transactions of the American Institute of Electrical Engineers Part III Power Apparatus and SystemsRequires access

A New 138-Kv 10,000-Mva Air-Blast Circuit Breaker

R. B. Shores, J. W. Beatty

Open publisher page 4 citations

Abstract

A new air-blast circuit breaker rated at 138 kv, 1,600 amperes, 10,000 mva (megavolt-amperes) has been developed for outdoor service on the lines of a large metropolitan utility. Designed as individual, double-break interrupter units mounted above conventional outdoor current transformers, the several columns of the breaker are mounted on a supporting framework and provided with a central control housing. Each interrupter is mounted inside its individual air storage tank for maximum interrupter efficiency. The use of porcelain for air tubes or interrupter housings to contain high-pressure air has been avoided in order to gain high safety factors in design. Dry air bleed for insulation protection is not required. The breaker is designed to handle a recovery voltage rate of 1,000 volts/μsec (per microsecond) at rated current interrupting value.

About this research paper

What this paper is about

A new air-blast circuit breaker rated at 138 kv, 1,600 amperes, 10,000 mva (megavolt-amperes) has been developed for outdoor service on the lines of a large metropolitan utility. Designed as individual, double-break interrupter units mounted above conventional outdoor current transformers, the several columns of the breaker are mounted on a supporting framework and provided with a central control housing. Each interrupter is mounted inside its individual air storage tank for maximum interrupter efficiency. The use of porcelain for air tubes or interrupter housings to contain high-pressure air has been avoided in order to gain high safety factors in design. Dry air bleed for insulation protection is not required. The breaker is designed to handle a recovery voltage rate of 1,000 volts/μsec (per microsecond) at rated current interrupting value.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new air-blast circuit breaker rated at 138 kv, 1,600 amperes, 10,000 mva (megavolt-amperes) has been developed for outdoor service on the lines of a large metropolitan utility. Designed as individual, double-break interrupter units mounted above conventional outdoor current transformers, the several columns of the breaker are mounted on a supporting framework and provided with a central control housing. Each interrupter is mounted inside its individual air storage tank for maximum interrupter efficiency. The use of porcelain for air tubes or interrupter housings to contain high-pressure air has been avoided in order to gain high safety factors in design. Dry air bleed for insulation protection is not required. The breaker is designed to handle a recovery voltage rate of 1,000 volts/μsec (per microsecond) at rated current interrupting value.

Key concepts: Interrupter, Circuit breaker, Sulfur hexafluoride circuit breaker, Electrical engineering, Residual-current device, Arc-fault circuit interrupter, Engineering, Switchgear

Related papers

Back to paper searchBrowse research topicsOriginal source
A New 138-Kv 10,000-Mva Air-Blast Circuit Breaker — Research Paper | ScholarLens