2010HSS Journal® The Musculoskeletal Journal of Hospital for Special SurgeryOpen access

High-Flexion Total Knee Replacement: Functional Outcome at One Year

Matthew S. Hepinstall, Amar S. Ranawat, Chitranjan S. Ranawat

Open full text 12 citations

Abstract

Implants designed for enhanced flexion offer the prospect of improved function after total knee replacement (TKR). Whereas most studies evaluating these implants have focused on the range of knee flexion achieved, this study investigated the quality of function in deep knee flexion. The influences of residual pain and maximum flexion angle on function in deep knee flexion were also examined. Eighty-three patients (100 knees) were prospectively followed for 1 year after TKR with a rotating-platform posterior-stabilized high-flexion prosthesis. Range of motion was measured and Knee Society scores were calculated. A questionnaire evaluated residual knee pain and function in high-flexion activities. Mean Knee Society score was 95, and mean knee flexion was 125°, yet 20% of patients could neither kneel, nor squat, nor sit on their heels. Fifty-seven percent were able to kneel without significant difficulty; 69% were able to squat without significant difficulty; and 46% were able to sit on their heels without significant difficulty. Function in deep flexion correlated with pain scores but did not correlate with knee flexion angles or Knee Society scores. Results 1 year after TKR with a rotating-platform posterior-stabilized high-flexion prosthesis are encouraging, but one in five patients remain significantly limited in high-flexion activities.

About this research paper

What this paper is about

Implants designed for enhanced flexion offer the prospect of improved function after total knee replacement (TKR). Whereas most studies evaluating these implants have focused on the range of knee flexion achieved, this study investigated the quality of function in deep knee flexion. The influences of residual pain and maximum flexion angle on function in deep knee flexion were also examined. Eighty-three patients (100 knees) were prospectively followed for 1 year after TKR with a rotating-platform posterior-stabilized high-flexion prosthesis. Range of motion was measured and Knee Society scores were calculated. A questionnaire evaluated residual knee pain and function in high-flexion activities. Mean Knee Society score was 95, and mean knee flexion was 125°, yet 20% of patients could neither kneel, nor squat, nor sit on their heels. Fifty-seven percent were able to kneel without significant difficulty; 69% were able to squat without significant difficulty; and 46% were able to sit on their heels without significant difficulty. Function in deep flexion correlated with pain scores but did not correlate with knee flexion angles or Knee Society scores. Results 1 year after TKR with a rotating-platform posterior-stabilized high-flexion prosthesis are encouraging, but one in five patients remain significantly limited in high-flexion activities.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Implants designed for enhanced flexion offer the prospect of improved function after total knee replacement (TKR). Whereas most studies evaluating these implants have focused on the range of knee flexion achieved, this study investigated the quality of function in deep knee flexion. The influences of residual pain and maximum flexion angle on function in deep knee flexion were also examined. Eighty-three patients (100 knees) were prospectively followed for 1 year after TKR with a rotating-platform posterior-stabilized high-flexion prosthesis. Range of motion was measured and Knee Society scores were calculated. A questionnaire evaluated residual knee pain and function in high-flexion activities. Mean Knee Society score was 95, and mean knee flexion was 125°, yet 20% of patients could neither kneel, nor squat, nor sit on their heels. Fifty-seven percent were able to kneel without significant difficulty; 69% were able to squat without significant difficulty; and 46% were able to sit on their heels without significant difficulty. Function in deep flexion correlated with pain scores but did not correlate with knee flexion angles or Knee Society scores. Results 1 year after TKR with a rotating-platform posterior-stabilized high-flexion prosthesis are encouraging, but one in five patients remain significantly limited in high-flexion activities.

Key concepts: Medicine, Knee flexion, Squat, Range of motion, Physical therapy, Prosthesis, Orthopedic surgery, Sports medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
High-Flexion Total Knee Replacement: Functional Outcome at One Year — Research Paper | ScholarLens